Atec Kikusui-PLZ-4W Series User Manual
Page 10
![background image](/manuals/319437/10/background.png)
10
P L Z - 4 W S E R I E S
[Meters]
*1
Displays the product of the
voltmeter reading and ammeter
reading.
*2
In a mode other the CP mode
*3
In CP mode
[Switching mode]
*1
The minimum time width is 10
μs. Between 5 kHz and 20 kHz,
t h e m a x i mu m d u t y c y c l e i s
limited by the mini-mum time
width.
[Slew rate]
*1
In CC mode. The maximum slew
rate of each range is 1/10th the
value in CR mode.
*2
Time to reach from 10 % to 90 %
when the current is varied from 2
% to 100 % of the rated current.
Meters
Model
PLZ164W
PLZ334W
PLZ1004W
PLZ164WA
PLZ664WA
Voltmeter
Range
H, M
0.00 V – 150.00 V
L
0.000 V – 15.000 V
Accuracy
±(0.1 % of rdg + 0.1 % of f.s)
Ammeter
Range
H, M
0.000 A
– 33.000 A
0.000 A
– 66.000 A
0.00 A
– 200.00 A
0.000 A
– 33.000 A
0.00 A
– 132.00 A
L
0.00 A
– 330.00 mA
0.00 A
– 660.00 mA
0.0000 A
– 2.0000 A
0.00 A
– 330.00 mA
0.000 A
– 1.3200 A
Accuracy
±(0.2 % of rdg + 0.3 % of f.s)
Wattmeter
*
1
Range
H, M
0.00 W
– 165.00 W
0.00 W
– 330.00 W
0.0 W
– 1000.0 W
0.00 W
– 165.00 W
0.00 W
– 660.00 W
L
*
2
0.000 W
– 49.500 W
0.000 W
– 99.000 W
0.00 W
– 300.00 W
0.000 W
– 49.500 W
0.000 W
– 198.00 W
L
*
3
0.0000 W
– 1.6500 W
0.0000 W
– 3.3000 W
0.000 W
– 10.000 W
0.0000 W
– 1.6500 W
0.0000 W
– 6.6000 W
Switching mode
Model
PLZ164W
PLZ334W
PLZ1004W
PLZ164WA
PLZ664WA
Operation mode
CC and CR
Duty cycle setting
5 % – 95 %
*
1
, 0.1 % step
Selectable frequency range
1 Hz – 20 kHz
Frequency
resolution
1 Hz – 10 Hz
0.1 Hz
10 Hz – 100 Hz
1 Hz
100 Hz – 1 kHz
10 Hz
1 kHz – 20 kHz
100 Hz
Frequency accuracy of setting
±(0.5 % of set)
Slew rate
Model
PLZ164W
PLZ334W
PLZ1004W
PLZ164WA
PLZ664WA
Setting range
*
1
Range
H
2.5 mA/
μs
– 2.5 A/
μs
5 mA/
μs
– 5 A/
μs
16 mA/
μs
– 16 A/
μs
2.5 mA/
μs
– 2.5 A/
μs
10 mA/
μs
– 10 A/
μs
M
250
μA/μs
– 250 mA/
μs
500
μA/μs
– 500 mA/
μs
1.6 mA/
μs
– 1.6 A/
μs
250
μA/μs
– 250 mA/
μs
1 mA/
μs
– 1 A/
μs
L
25
μA/μs
– 25 mA/
μs
50
μA/μs
– 50 mA/
μs
160
μA/μs
– 160 mA/
μs
25
μA/μs
– 25 mA/
μs
100
μA/μs
– 100 mA/
μs
Resolution
See below.
Accuracy of setting
*
2
±(10 % of set + 5
μs)
Slew rate resolution
PLZ164W
PLZ164WA
Setting
25
μA/μs
– 250
μA/μs
250
μA/μs
– 2.5 mA/
μs
2.5 mA/
μs
– 25 mA/
μs
25 mA/
μs
– 250 mA/
μs
250 mA/
μs
– 2.5 A/
μs
Resolution
100 nA
1
μA
10
μA
100
μA
1 mA
PLZ334W
Setting
50
μA/μs
– 500
μA/μs
500
μA/μs
– 5 mA/
μs
5 mA/
μs
– 50 mA/
μs
50 mA/
μs
– 500 mA/
μs
500 mA/
μs
– 5 A/
μs
Resolution
200 nA
2
μA
20
μA
200
μA
2 mA
PLZ664WA
Setting
100
μA/μs
– 1 mA/
μs
1 mA/
μs
– 10 mA/
μs
10 mA/
μs
– 100 mA/
μs
100 mA/
μs
– 1 A/
μs
1 A/
μs
– 10 A/
μs
Resolution
400 nA
4
μA
40
μA
400
μA
4 mA
PLZ1004W
Setting
160
μA/μs
– 1.6 mA/
μs
1.6 mA/
μs
– 16 mA/
μs
16 mA/
μs
– 160 mA/
μs
160 mA/
μs
– 1.6 A/
μs
1.6 A/
μs
– 16 A/
μs
Resolution
600 nA
6
μA
60
μA
600
μA
6 mA
Soft start
Model
PLZ164W
PLZ334W
PLZ1004W
PLZ164WA
PLZ664WA
Operation mode
CC and CR
Selectable time range
1, 2, 5, 10, 20, 50, 100, or 200 ms
Time accuracy
±(30 % of set +100
μs)
Remote sensing
Model
PLZ164W
PLZ334W
PLZ1004W
PLZ164WA
PLZ664WA
Voltage that can be compensated
2 V for a single line
Protection function
Model
PLZ164W
PLZ334W
PLZ1004W
PLZ164WA
PLZ664WA
Overvoltage protection (OVP)
Turns off the load at 110 % of the rated voltage
Overcurrent protection (OCP)
0.03 A – 36.3 A
0.06 A – 72.6 A
0.2 A – 220 A
0.03 A – 36.3 A 0.13 A – 145.2 A
Or 110 % of the maximum current of each range
Overpower protection (OPP)
0.1 W – 181.5 W
0.3 W – 363 W
1 W – 1 100 W
0.1 W – 181.5 W
0.6 W – 726 W
Or 110 % of the maximum power of each range
Load off or limit selectable
Overheat protection (OHP)
Turns off the load when the heat sink temperature reaches 95 °C
Undervoltage protection (UVP)
Turns off the load when detected.
Can be set in the range of 0 V to 150 V or Off.
Reverse connection protection (REV)
By diode and fuse. Turns off the load when an alarm occurs.