Atec Kikusui-PLZ-4W Series User Manual
Page 11
11
P L Z - 4 W S E R I E S
Sequence function
Model
PLZ164W
PLZ334W
PLZ1004W
PLZ164WA
PLZ664WA
Normal
sequence
Operation mode
CC, CR, CV, or CP
Maximum number of steps
256
Step execution time
1 ms – 999 h 59 min
Time resolution
1 ms (1 ms – 1 min)/100 ms (1 min – 1 h)/1 s (1 h – 10 h)/
10 s (10 h – 100 h)/1 min (100 h – 999 h 59 min)
Fast
sequence
Operation mode
CC or CR
Maximum number of steps
1024
Step execution time
25
μs – 100 ms
Time resolution
25
μs (25 μs – 100 μs)/100 μs (100 μs – 100 ms)
Others, Common specifications
Model
PLZ164W
PLZ334W
PLZ1004W
PLZ164WA
PLZ664WA
Elapsed time display
Measures the time from load on to load off. On/Off selectable.
Measures from 1 s up to 999 h 59 min 59 s
Auto load off timer
Automatically turns off the load after a specified time elapses.
Can be set in the range of 1 s to 999 h 59 min 59 s or off
Front panel
BNC connector
TRIG OUT
Trigger output: Approx. 4.5 V, pulse width: Approx. 2
μs, output impedance: Approx. 500 Ω
Outputs a pulse during sequence operation and switching operation.
I MON OUT
Current monitor output
1 V f.s (H or L range) and 0.1 V f.s (M range)
Communication
function
GPIB
IEEE std. 488.1-1978
SH1, AH1, T6, L4, SR1, RL1, PP0, DC1, DT1, C0, E1
Supports the SCPI and IEEE std. 488.2-1992 command set
Sets panel functions except the power switch and reads measured values
RS-232C
D-SUB 9-pin connector (conforms to EIA-232-D)
Sets panel functions except the power switch and reads measured values
Supports the SCPI and IEEE std. 488.2-1992 command set
Baud rate: 2400, 4800, 9600, 19200 bps
Data length: 8-bit, Stop bit: 1, 2-bit, Parity bit: None, Flow control: Xon/Xoff
USB
Conforms to USB 2.0 Specifications and USBTMC-USB488 Device Class Specifications
Sets panel functions except the power switch and reads measured values
Communication speed 12 Mbps (Full speed)
General Specifications
Model
PLZ164W
PLZ334W
PLZ1004W
PLZ164WA
PLZ664WA
Input voltage range
100 VAC – 240 VAC
(90 VAC – 250 VAC)
Single phase, continuous
100 VAC – 120 VAC/200 VAC – 240 VAC
(90 VAC – 132 VAC/180 VAC – 250 VAC)
Single phase
Input frequency range
47 Hz – 63 Hz
Power consumption
80 VAmax
90 VAmax
160 VAmax
450 VAmax
1500 VAmax
Inrush current
45 A
80 A
Operating temperature range
0 °C – 40 °C
Operating humidity range
20 % – 85 % RH (without condensation)
Storage temperature range
–25 °C – 70 °C
Storage humidity range
90 % RH or less (without condensation)
Isolation voltage
±500 V
Insulation
resistance
Primary - input terminal
500 VDC, 30 M
Ω or more (ambient humidity of 70 % RH or less)
Primary - chassis
500 VDC, 30 M
Ω or more (ambient humidity of 70 % RH or less)
Withstand
voltage
Primary - input terminal
No abnormalities at 1500 VAC for 1 minute.
Primary - chassis
No abnormalities at 1500 VAC for 1 minute.
Dimensions (mm)
See outline drawing
Weight
Approx. 7 kg
Approx. 8 kg
Approx. 15 kg
Approx. 7.5 kg
Approx. 16 kg
Battery backup
Backs up setup information
Accessories
Power cord
× 1 pc. (with SVT3, 18AWG, 3-pin plug, cable length of 2.4 m), Load input
terminal cover
× 1 piece (2 lock plates provided), Set of screws for the load input terminal
× 2 sets (bolts, nuts, and spring washers), Setup guide × 1 piece(Japanese,English),
Quick Reference(Japanese:1 piece, Englis:1 piece),CD-ROM × 1 piece
*
3
Electromagnetic compatibility
(EMC)
*
1
Conforms to the requirements of the following directive and standard.
EMC Directive 89/336/EEC
EN61326:1997/A2:2001
Emissions: Class A
Immunity: Minimum immunity test requirements
EN61000-3-2:2000
EN61000-3-3:1995/A1:2001
Safety
*
1
,
*
2
Conforms to the requirements of the following directive and standard.
Low Voltage Directive 73/23/EEC
EN61010-1:2001
Class I
Pollution degree 2
[General Specifications]
*1
Only on models that have CE
marking on the panel.
Not applicable to custom order
models.
*2
This instrument is a Class I
equipment. Be sure to ground
the protective conductor terminal
of the instrument.
The safety of the instrument is
n o t g u a r a n t e e d u n l e s s t h e
instrument is grounded properly.
*3
C o n t a i n s A p p l i c a t i o n &
Samples,User
,
s manual,the
Communication Interface Manual
and KI-VISA.