Time domain

Frequency domain

1,000 points

Convert 1,000 to 10,000 points

Before scaling

After scaling

Waveform in the MEM function

Recalculate by changing the number of calculation points after measurement

Even for measurement data currently based on a lower number of

calculation points, it is possible to increase the number later and

perform analysis again. For example, data measured at a setting of

1,000 points can be converted and reanalyzed with a 10,000 point

setting. This will result in a tenfold increase in frequency analysis

resolution. Of course, the opposite is also possible, going for example

from 10,000 points to 1,000 points.

* Recalculation with a different number of calculation points is not possible if frequency

averaging is set to ON.

Decibel-based scaling

Decibel-based scaling as requested by numerous customers is now

possible. There is no more need to make logarithmic conversions on

the side with an electronic calculator. The

8847 can accept input of

overall values (power spectrum sum) in dB, with the capability for

easy scaling. Signals from noise level meters and similar equipment

can therefore be read directly.

function available from version 2.00 onward

- Frequency area data analysis (FFT function) -
- Electrical distortion analysis/mechanical vibration analysis -

Highlights

This function comprises single-signal FFT for tasks such as frequency

component analysis, dual-signal FFT for transfer function analysis,

and octave analysis for acoustic measurements. The signal source for

analysis are specified sections from waveform data captured using the

Memory function.

* The selectable range is 1,000 to 10,000 data points.

Compared to the predecessor model

8841, processing speed is about

1.6 times faster (internal clock ratio) when performing the most time-

intensive analysis calculation under the same conditions.

FFT analysis function

To use measurement data captured with the Memory function, the Jog & Shuttle

knobs serve to specify analysis points, and processing results can now be

displayed at the same time. Compared to earlier models such as the

8855 and

8841, operation has been significantly streamlined by eliminating the need to

go back and forth between the Memory function and the FFT function. It is also

possible to view raw data measured with the Memory function and processing

results obtained from stored waveforms side by side. This makes it possible

to check the effects of window functions while viewing spectrum waveforms,

resulting in a dramatic improvement in operation convenience during use of the

analysis functions.

FFT analysis from memory waveform data

Specify an analysis point