FTB-8120NGE/8130NGE Power Blazer

Optical Transport Network Testing

OTN as per ITU-T G.709 has recently introduced two new concepts: ODU0 and ODUflex. ODU0 is a new virtual container
of 1.25 Gbit/s bandwidth specifically defined for efficiently mapping Gigabit Ethernet services over OTN. As for ODUflex,
it is the most efficient sub-wavelength bandwidth management capability for transport line rates of 10 Gbit/s, 40 Gbit/s and
upcoming 100 Gbit/s. ODUflex allows providers to interconnect routers in ways that enable efficient bandwidth growth in steps
of 1.25 Gbit/s, eliminating the need to allocate a full fixed-rate ODU container to each connection, and allowing service providers
to transport efficiently and seamlessly across lower-cost optical infrastructures.

With OTN deployments rapidly increasing, so is the need for smaller, field-oriented OTN test equipment. The FTB-8120NGE/8130NGE
Power Blazer modules offer OTN test capabilities for verifying compliancy with ITU-T G.709 standards. The tests include:

OTU1 (2.7 Gbit/s) and OTU2

(10.7 Gbit/s) bit rates

ODU0 (1.25 Gbit/s) container with

Gigabit Ethernet and SONET/SDH
client signals mapping

ODUflex with Ethernet client signal

mapping

Overclocked OTU2 rates: OTU1e

(11.0491 Gbit/s), OTU2e (11.0957
Gbit/s), OTU1f (11.2701 Gbit/s) and
OTU2f (11.3176 Gbit/s)

Unframed optical signal testing at

10.7 Gbit/s, 11.0491 Gbit/s,
11.0957 Gbit/s, 11.2701 Gbit/s and
11.3176 Gbit/s rates

Synchronous mapping of SONET/SDH

signals within OTN as well as
synchronous and asynchronous
demapping

Forward error correction (FEC) testing

Service disruption time (SDT)

measurements

Multichannel SDT measurements and

real-time error/alarm monitoring for all
ODU0 channels

Round-trip delay (RTD) measurements

OTU, ODU, OPU overhead

manipulation and monitoring

OTU, ODU (including ODU TCM),

OPU layer alarms/errors generation
and analysis

OTU, ODU (including ODU TCM)

trace messages

Mux/demux of ODU1/ODU2 testing;

generation of four ODU1 into a single
ODU2 structure and transporting it
over a single wavelength

ODU multiplexing alarm-generation and

analysis

Through mode analysis

Intrusive Through mode

EoOTN testing using internally

generated 10 GigE LAN and mapping
onto OTU1e and OTU2e rates

10 GigE LAN mapping into OTU2

using GFP-F

G.709 DUT

OTUk Signal

Power Blazer modules support G.709
testing in either the FTB-200 or FTB-500.