beautypg.com

Modulation analysis specifications – Atec Agilent-N9320B User Manual

Page 8

background image

8

Modulation Analysis Specifications

Supplemental information

Demodulation

Frequency range

10 MHz to 3 GHz

Carrier power accuracy

± 2 dB

± 1 dB typical

Input power

-30 to +20 dBm

Auto attenuation

Carrier power displayed resolution

0.01 dBm

AM measurement (included in Option AMA)

Modulation rate

20 Hz to 100 kHz

Accuracy

1 Hz, nominal

Modulation rate < 1 kHz

< 0.1% modulation rate, nominal

Modulation rate ≥ 1 kHz

Depth

5 to 95%

Accuracy

± 4% nominal

FM measurement (included in Option AMA)

Modulation rate

20 Hz to 200 kHz

Accuracy

1 Hz, nominal

Modulation rate < 1 kHz

< 0.1% modulation rate, nominal

Modulation rate ≥ 1 kHz

Deviation

20 Hz to 400 kHz

Accuracy

± 4% nominal

ASK measurement (included in Option DMA)

Symbol rate range

200 Hz to 100 kHz

Modulation depth/index range

10 to 90%

Accuracy

± 4% of reading, nominal

Displayed resolution

0.1%

FSK measurement (included in Option DMA)

Symbol rate range

1 to 100 kH

FSK deviation range

1 to 400 kHz

Accuracy

± 4% nominal

β ≥1 and β≤4, β is the ratio of frequency
deviation to symbol rate

Displayed resolution

0.01 Hz