20

Models

Synthesized CW Generators

68017C, 0.01 to 8.4 GHz

69017B, 0.01 to 8.4 GHz

68037C, 2 to 20 GHz

69037B, 2 to 20 GHz

68047C, 0.01 to 20 GHz

69047B, 0.01 to 20 GHz

68067C, 0.01 to 40 GHz

69067B, 0.01 to 40 GHz

68077C, 0.01 to 50 GHz

69077B, 0.01 to 50 GHz

68087C, 0.01 to 60 GHz

69087B, 0.01 to 60 GHz

68097C, 0.01 to 65 GHz

69097B, 0.01 to 65 GHz

Synthesized Signal Generators

68117C, 0.01 to 8.4 GHz

69117B, 0.01 to 8.4 GHz

68137C, 2 to 20 GHz

69137B, 2 to 20 GHz

68147C, 0.01 to 20 GHz

69147B, 0.01 to 20 GHz

68167C, 0.01 to 40 GHz

69167B, 0.01 to 40 GHz

68177C, 0.01 to 50 GHz

69177B, 0.01 to 50 GHz

68187C, 0.01 to 60 GHz

69187B, 0.01 to 60 GHz

68197C, 0.01 to 65 GHz

69197B, 0.01 to 65 GHz

Synthesized High Performance Signal Generators

68317C, 0.01 to 8.4 GHz

69317B, 0.01 to 8.4 GHz

68337C, 2 to 20 GHz

69337B, 2 to 20 GHz

68347C, 0.01 to 20 GHz

69347B, 0.01 to 20 GHz

68367C, 0.01 to 40 GHz

69367B, 0.01 to 40 GHz

68377C, 0.01 to 50 GHz

69377B, 0.01 to 50 GHz

68387C, 0.01 to 60 GHz

69387B, 0.01 to 60 GHz

68397C, 0.01 to 65 GHz

69397B, 0.01 to 65 GHz

Options

Option 1, Rack Mounting:

Rack mount kit containing a set

of track slides (90˚ tilt capability), mounting ears, and front panel
handles to let the instrument be mounted in a standard 48 cm
equipment rack.

Option 2A, Step Attenuator:

Adds a 10 dB/step attenuator

for models having a high-end frequency of

≤20 GHz. Rated

RF output power is reduced.

Option 2B, Step Attenuator:

Adds a 10 dB/step attenuator

for models having a high-end frequency of

≤ 40 GHz. Rated

RF output power is reduced.

Option 2C, Step Attenuator:

Adds a 10 dB/step attenuator

for models having a high-end frequency of

≤ 50 GHz. Rated

RF output power is reduced.

Option 2D, Step Attenuator:

Adds a 10 dB/step attenuator

for models having a high-end frequency of

≤ 60 GHz. Rated

RF output power is reduced.

Option 2E, Electronic Step Attenuator:

Adds a 10 dB/step

electronic attenuator for models having a high-end frequency of
≤8.4 GHz. Rated RF output power is reduced.

Option 2F, Electronic Step Attenuator:

Adds a 10 dB/step

electronic attenuator for models having a high-end frequency of
≤20 GHz. Rated RF output power is reduced.

Option 6, Phase Modulation (

ΦM) (683xxC and 693xxB):

Provides phase modulation capability. FM input, FM output
and FM generator become FM/

ΦM input, FM/ΦM output and

FM/

ΦM generator.

Option 7, Delete AM/FM Generators (683xxC and 693xxB):

Deletes the internal AM and FM generators. External AM and FM
capability remains unchanged. (Not available in combination with
Option 8 or Option 20.)

Option 8, Internal Power Measurement (683xxC and

693xxB):

Adds an internal power measurement function that is

compatible with Anritsu 560-7, 5400-71 or 6400-71 series
detectors. (Not available in combination with Option 7)

Option 9, Rear Panel RF Output:

Moves RF output connector

to the rear panel.

Option 10, User-defined Modulation Capability (683xxC,

and 693xxB):

Provides user-defined waveform capability.

Requires controller (not included). Includes cable and Windows

®

based software.

Option 11, 0.1 Hz Frequency Resolution:

Provides frequency

resolution of 0.1 Hz.

Option 14, Anritsu 360B VNA Compatibility:

Modifies rack mounting hardware to mate the unit in an Anritsu
360B VNA console.

Option 15A, High Power Output (680xxC, 681xxC, 690xxB

and 691xxB):

Adds high power RF components to the

instrument in the 2

−20 GHz frequency range.

Option 15B, High Power Output (683xxC and 693xxB):

Adds high-power RF components to the instrument in the
2–20 GHz frequency range.

Option 16, High Stability Time Base:

Adds an ovenized,

10 MHz crystal oscillator as a high-stability time base. Derate
phase noise specification at 10 Hz offset by 8 dB.

Option 17A, Delete Front Panel (68100C, 68300C, 69100B

and 69300B):

Deletes the front panel for use in remote control

applications where a front panel display and keyboard control are
not needed.

Option 17B, Delete Front Panel (68000C and 69000B):

Deletes the front panel for use in remote control applications
where a front panel display and keyboard control are not needed.

Option 18, mmWave Bias Output:

Adds rear panel bias output

to drive 54000-xWRxx millimeter wave source modules. BNC
Twinax connector. (Not available in combination with Option 20.)

Option 19, SCPI Programmability

: Adds GPIB command

mnemonics complying with Standard Commands for
Programmable Instruments (SCPI), Version 1993.0. SCPI
programming complies with IEEE 488.2–1987.

Option 20, SCAN Modulator

: Adds an internal SCAN modulator

for simulating high-depth amplitude modulated signals in models
68337C, 68347C, 69337B and 69347B only. Requires an external
modulating signal input. (Not available in combination with
Option 7, Option 18, or Option 22.)

Option 21A, (690xxB, 691xxB):

Low Phase Noise, Non-pulsed Digital Downconverter replaces
standard analog downconverter on units with low frequency limit
of 10 MHz. CW only from 10 MHz to 2.2 GHz

Option 21B, (693xxB):

Low Phase Noise, Pulsed Digital

Downconverter replaces standard analog downconverter on units
with low frequency limit of 10 MHz. CW with pulse modulation
from 10 MHz to 2.2 GHz

Option 22, 0.1 Hz to 10 MHz Audio Frequency:

Adds CW and step sweep frequency coverage below 10 MHz.
No modulation is available below 10 MHz. Derate output power by
1 dB for

≤20 GHz and 2 dB for >20 GHz (Not available in

combination with Option 20.)

ORDERING INFORMATION