Atec Anritsu-MG3670 Series User Manual
Page 8
![background image](/manuals/318630/8/background.png)
For product ordering information, see pages 4-7.
www.anritsu.com
297
RADIO COMMUNICATIONS, EMI MEASURING TEST INSTRUMENTS
6
Burst repetition rate
20 ms (PPC), 40 ms (PDC_H)
PDC
Slot configuration
For device, up/down communication channel, up VOX control
PDC_H
Output slot select
On/off selectable for any slots of slot 0 to slot 2 (PDC)/slot 5 (PDC_H)
*
excluding all slots off
Edit function
SW/CC/SACCH: Any data, TCH: PN9, PN15*
1
selectable
Scramble function
TCH + SF + SACCH scramble on/off, any scramble code setting
Burst repetition rate
5 ms
Slot configuration
For device, up/down communication channel, VOX control
Output slot select
On/off selectable for any slots of slot 1 to slot 4 (excluding all slots off)
PHS
Edit function
UW/SA: Any data, TCH: PN9, PN15*
1
selectable
Scramble function
TCH + CRC, scramble and secret scramble on/off, any scramble code setting
Adjacent channel
power leakage ratio
≤–74 dB (600/900 kHz offset, ±96 kHz band, ≥10 MHz)*
2
Burst repetition rate
80 ms
TFTS
Slot configuration
For device, up/down communication channel
Output slot select
On/off selectable for any slots of slot 0 to slot 16 (Device/UP TCH: Slots 16 is off at all time, excluding all slots off)
Edit function
S: Any data, DATA: PN9, PN15*
1
selectable
Burst repetition rate
4.615 ms
GSM, PCN
Slot configuration
For device, normal burst (communication channel)
(DCS1800)
Output slot select
On/off selectable for any slots of slot 0 to slot 7 (excluding all slots off)
Edit function
TS: Any data, E: PN9, PN15*
1
selectable
Burst repetition rate
2 ms
CT2
Slot configuration
Up/down communication channel (MUX 1.2, MUX 1.4, MUX 2)
Edit function
D, B, Da, Db, CHM/SYNC data selectable
Scramble function
B scramble on/off, any scramble code setting
Burst repetition rate
10 ms
Slot configuration
For device, up/down communication channel
Full slot: Slot 0 to slot 11 (down channel), slot 12 to slot 23 (up channel)
Output slot select
Half slot: Slot 0-0 to slot 11-1 (down channel), slot 12-0 to slot 23-1 (up channel)
DECT
Double slot: Slot 0 to slot 10 (down channel), slot 12 to slot 22 (up channel)
*
On/off selectable for any slots (excluding all slots off)
S, H, T: Any data
Edit function
D: PN15/PN9*
1
, all-0 or all-1 selectable (for device evaluation)
D: PN15/PN9*
1
, TEST or REP-8 bits any data selectable (for communication channel)
Burst repetition rate
2.5 ms
Slot configuration
For device, up/down communication channel
PACS
Output slot select
On/off selectable for any slots of slot 0 to slot 7 (excluding all slots off)
Edit function
PN: PN9, PN15*
1
selectable (for device), DE/SC/R/SYC/PCC: Any data, FC: PN9*
1
, PN15*
1
, all-0 or all-1 selectable
(PN15 selectable only for 1 slot)
Burst repetition rate
10 ms
Slot configuration
For device, up/down communication channel
WCPE
Full slot: Slot 0 to slot 11 (down), slot 12 to slot 23 (up); Half slot: Slot 0-0 to slot 11-1 (down), slot 12-0 to slot 23-1 (up);
Output slot select
Double slot: Slot 0 to slot 10 (down), slot 12 to slot 22 (up)
*
On/off selectable for any slots (excluding all slots off)
S/H/T: Any data
Edit function
D: PN9*
1
, PN15*
1
, all-0 or all-1 selectable (for device)
D: PN9*
1
, PN15*
1
, TEST or REP 8-bits any data selectable (for communication channel)
Burst repetition rate
5 ms
Slot configuration
For device, up/down communication channel, VOX control, sync burst
Output slot select
On/off selectable for any slots of slot 1 to slot 4 (excluding all slots off)
PHS
Edit function
UW/SA etc.: Any data, TCH: PN9, PN15*
1
selectable
Scramble function
TCH + CRC, scramble on/off, any scramble code setting
Adjacent channel
leakage power ratio
≤–74 dB (600/900 kHz offset, ±96 kHz band, ≥10 MHz)*
2
Burst repetition rate
V + D mode: 1.02; Excluding CH13, 255 to 30000 symbols; CH13
PDO mode: 1.00; Excluding CH14, 126 to 30000 symbols; CH14
Following channel types selectable
Burst pattern
V + D mode: CH1, CH2, CH3, CH4, CH13; Downlink, CH7, CH8, CH9, CH10, CH11; Uplink
TETRA
PDO mode: CH5, CH6, CH14; Downlink, CH12; Uplink
Slot configuration
V + D mode: DEVICE, NORMAL, SYNC; Downlink, DEVICE NORMAL, CONTROL; Uplink
PDO mode: NORMAL, SYNC; Downlink, START, EVEN, ODD, END; Uplink
V + D mode: On/off selectable for any slots of slot 1 to slot 4 (excluding CH13 and all slots off)
Output slot select
Frame 1 to Frame 17 set to the same values
PDO mode: Variable slot numbers of slot 1 to slot 150 (excluding CH14)
Continued on next page