Power meters & sensors selection guide – Atec Anritsu-ML2400 Series User Manual
Page 10

10
PN: 11410-00423 Rev. H
ML2430A, ML2480B, ML2490A TDS
Ordering Information
Power Meters & Sensors ML2430A, ML2480B, ML2490A
Power Meters & Sensors Selection Guide
Choose the right power meter and power sensor for your measurement application.
Power Sensors
Standard
Diode
(High Accuracy)
Diode
Universal
Wideband
Pulse
Thermal
Model Number
MA2470D
Series
MA2440D Series
MA2480D
Series
MA249XA Series
MA2411B
MA2400xA
Power Measurement
Average (RMS)
Average (RMS)
Average (RMS)
Average (RMS),
Peak
Average (RMS),
Peak
Average (RMS)
Measurement Application
(Examples)
CW, GMSK,
GFSK, 8PSK
CW, GMSK
CW, GMSK,
GFSK, 8PSK,
QPSK, QAM
CW, GMSK,
8PSK, QPSK,
QAM
Pulse, QAM
Any Modulation
TDMA, FDMA,
IS136
TDMA, FDMA
TDMA, FDMA,
CDMA, OFDM,
Radar
TDMA, FDMA,
CDMA, OFDM,
Radar
Radar, OFDM
Any Access
Scheme
Compatible Power Meters
ML24xxA/B
ML24xxA/B
ML24xxA/B
ML2480A/B,
ML2490A
ML2480A/B,
ML2490A
ML24xxA/B
Power Meter Models
ML2430A Series
ML2495A Pulse Power Meter, Single Input
ML2400A-05 Front Bail Handle
ML2496A Pulse Power Meter, Dual Input
ML2400A-06 Rear Mount Input A on ML2437A
ML2487B Wideband Power Meter, Single Input
ML2400A-07 Rear Input A and Reference on ML2437A
ML2488B Wideband Power Meter, Dual Input
ML2400A-08 Rear Mount Inputs A, B and Reference on ML2438A
ML2437A CW Power Meter, Single Input
ML2400A-09 Rear Mount Inputs A and B on ML2438A
ML2438A CW Power Meter, Dual Input
2000-1603 NiMH Battery
2000-996-R Desktop Battery Charger with Power Supply
ML2490A Series
2000-1534-R Desktop Battery Charger (for use in Japan only)
ML2400A-05 Front Bail Handle
2000-1538-R 3 m Sensor Cable
ML2490A-06 Rear Mount Input A on ML2495A
2000-1539-R 5 m Sensor Cable
ML2490A-07 Rear Input A and Reference on ML2495A
2000-1540-R 10 m Sensor Cable
ML2490A-08 Rear Mount Inputs A, B and Reference on ML2496A
2000-1541-R 30 m Sensor Cable
ML2490A-09 Rear Mount Inputs A, B on ML2496A
2000-1542-R 50 m Sensor Cable
ML2490A-98 Calibration to ISO 17025 and/or ANSI/NCSL Z540
2000-1543-R 100 m Sensor Cable
ML2490A-99 Premium Calibration
2000-1545 Bulkhead Adapter
13000-00238 Hard Copy Operation Manual
a
a. English and Japanese soft copy manual included standard on product disc.
10585-00001 Hard Copy Operation and Programming Manual
a
13000-00239 Hard Copy Programming Manual
a
10585–00003 Hard Copy Maintenance Manual
13000-00164 Hard Copy Maintenance Manual
ML2400A-98 Calibration to ISO 17025 and/or ANSI/NCSL Z540
ML2400A-99 Premium Calibration
ML2480B Series
Options 5, 2400-82, and 2400-83 are mutually exclusive for any given
ML2430A.
Options 6, 7, 8 and 9 are mutually exclusive for any given ML2430A unit.
Pulse/modulated performance only specified with 1.5 m sensor cable
length.
ML2480B-005 Front Bail Handle
ML2480B-006 Rear Mount Input A on ML2487A
ML2480B-007 Rear Input A and Reference on ML2487A
ML2480B-008 Rear Mount Inputs A, B, and Reference on ML2488A
ML2480B-009 Rear Mount Inputs A, B on ML2488A
ML2480B-015 Factory Fitted 50 MHz and 1 GHz Calibrator
(required by MA2411B Sensor)
Standard Accessories (all models)
ML2480B-098 Calibration to ISO 17025 and/or ANSI/NCSL Z540
2300-283 Power Meters and Sensors Product Disc
- Documentation and Literature
- PowerMax (ML249xA and ML248xB only)
- PowerSuite (ML243xA only)
- PowerXpert (USB Power Sensors only)
Power Cord (for destination country)
1.5 m Sensor Cord (one per meter input)
Certificate of Calibration (also included with sensors)
ML2480B-099 Premium Calibration
13000-00238 Hard Copy Operation Manual
a
13000-00239 Hard Copy Programming Manual
a
13000-00164 Hard Copy Maintenance Manual
Options 5, 2400-82, and 2400-83 are mutually exclusive for any given
ML2480B/90A.
Options 6, 7, 8 and 9 are mutually exclusive for any given ML2480B/90A.