General specifications – Atec Chroma-62000H Series User Manual
Page 7
Programming & Measurement Resolution
Voltage (Front Panel )
10 mV
Current (Front Panel)
10 mA
Voltage (Digital Interface)
0.002% of Vmax
Current (Digital Interface)
0.002% of Imax
Voltage (Analog Interface )
0.04% of Vmax
Current (Analog Interface )
0.04% of Imax
Remote Interface
Analog programming
Standard
USB
Standard
RS232
Standard
RS485
Standard
GPIB
Optional
Ethernet
Optional
System bus(CAN)
Standard for master/slave control
Programming Accuracy
Voltage (Front Panel and Digital Interface )
0.1% of Vmax
Current (Front Panel and Digital Interface )
0.3% of Imax
Voltage (Analog Interface)
0.2% of Vmax
Current (Analog Interface)
0.3% of Imax
GPIB Command Response Time
Vout setting
GPIB send command to DC source receiver <20ms
Measure V&I
Under GPIB command using Measure <25ms
Analog Interface (I/O)
Voltage and Current Programming inputs (I/P)
0-10Vdc / 0-5Vdc / 0-5k ohm / 4-20 mA of F.S.
Voltage and Current monitor output (O/P)
0-10Vdc / 0-5Vdc / 4-20mA of F.S.
External ON/OFF (I/P)
TTL:Active Low or High(Selective)
DC_ON Signal (O/P)
Level by user define. ( Time delay = 1 ms at voltage slew rate of 10V/ms.)
CV or CC mode Indicator (O/P)
TTL Level High=CV mode ; TTL Level Low= CC mode
OTP Indicator (O/P)
TTL: Active Low
System Fault indicator(O/P)
TTL: Active Low
Auxiliary power supply(O/P)
Nominal supply voltage : 12Vdc / Maximum current sink capability: 10mA
Safety interlock(I/P)
Time accuracy: <100ms
Remote inhibit(I/P)
TTL: Active Low
Series & Parallel Operation
*1
Master / Slave control via CAN for 10 units up to 150KW. (Series: two units / Parallel: ten units )
Auto Sequencing(List Mode)
Number of program
10
Number of sequence
100
Dwell time Range
5ms - 15000S
Trig. Source
Manual / Auto / External
Auto Sequencing (Step Mode)
Start voltage
0 to Full scale
End voltage
0 to Full scale
Run time
10ms - 99hours
Input Specification
AC input voltage 3phase , 3 wire + ground
208/220 Vac(operating range 187 -242 Vac) *2
380/400 Vac(operating range 342 - 440 Vac)
440/480 Vac(operating range 396 - 528 Vac) *2
AC frequency range
47-63 Hz
Max Current(each phase)
208/220 Vac
5KW Model:39A
10KW Model:66A
15KW Model:91A
380/400 Vac
5KW Model:22A
10KW Model:37A
15KW Model:50A
440/480 Vac
5KW Model:19A
10KW Model:32A
15KW Model:44A
General Specification
Maximum Remote Sense Line Drop Compensation
<100V model: 5% of full scale voltage per line(10% total)
>100V model :2% of full scale voltage per line (4% total)
Operating Temperature Rage
0°C ~ 50°C
Storage Temperature Rage
-40°C ~ +85°C
Dimension (HxWxD)
132.8 x 428 x 610 mm / 5.23 x 16.85 x 24.02 inch
Weight
5KW Model : Approx. 23 kg / 50.66 lbs
10KW Model : Approx. 29 kg / 63.88 lbs
15KW Model : Approx. 35 kg / 77.09 lbs
gENEral SPEciFicatiONS
Note*1
: To parallel more than 5 units, please contact factory.
Note*2
: Call for availability.