Performance characteristics

(continued)

Measurement features

Automatic measurements

Measurements are continuously updated. Cursors track last selected measurement.

Voltage

Peak-to-peak, maximum, minimum, average, amplitude, top, base, overshoot, preshoot, RMS,

standard deviation, Ratio (dB)

Time

Frequency, period, + width, – width and duty cycle on any channel. Rise time, fall time, X at max Y

(time at max volts), X at min Y (time at min volts), delay, and phase on oscilloscope channels only.

Counter

Built-in 5-digit frequency counter on any channel. Counts up to the oscilloscope’s bandwidth.

Threshold definition

Variable by percent and absolute value; 10%, 50%, 90% default for time measurements

Cursors

Manually or automatically placed readout of horizontal (X, ΔX, 1/ΔX) and vertical (Y, ΔY). Tracking

Cursors provides an additional mode for cursor positioning beyond the current manual method. When

cursor tracking is enabled, changing a cursor's x-axis position results in the y-axis cursor tracking the

corresponding y-axis (voltage, current, etc.) value. Additionally logic or scope channels

can be displayed as binary or hex values.

Waveform math

f (g(t))

g(t): { 1, 2, 3, 4, 1-2, 1+2, 1x2, 3-4, 3+4, 3x4}

f(t): { 1-2, 1+2, 1x2, 3-4, 3+4, 3x4, FFT(g(t)), differentiate d/dt g(t), integrate ∫ g(t) dt, square

root √g(t) } Where 1,2,3,4 represent analog input channels 1, 2, 3, and 4

Note: Channels 3 and 4 only available on DSO5xx4A models

Measurement Statistics

Statistical data for enabled measurements such as mean, min, max, standard deviation and count

FFT
Points

Up to 10 kpts in precision mode

Source of FFT

1, 2, 1+2, 1-2, 1x2, DSO5xx4A: 3, 4, 3+4, 3-4, 3x4;

where 1, 2, 3, 4 represent the analog channel inputs 1, 2, 3, and 4

Window

Rectangular, flattop, hanning, Blackman Herris

Noise floor

–50 to –90 dB depending on averaging

Amplitude

Display in dBV, dBm at 50 Ω

Frequency resolution

0.05/time per div

Maximum frequency

50/time per div

Storage
Save/recall

10 setups and traces can be saved and recalled using internal non-volatile memory.

Optional secure environment mode ensures setups and traces are stored to internal volatile memory so

data is erased when power is removed. Compliant to NISPOM Chapter 8 requirements.

Storage type and format

USB 1.1 host ports on front and rear panels

Image formats: BMP (8-bit), BMP (24-bit), PNG (24-bit)

Data formats: X and Y (time/voltage) values in CSV format, ASCII XY format, BIN format

Trace/setup formats: Recalled

I/O
Standard ports

USB 2.0 high speed device, two USB 1.1 host ports, 10/100-BaseT LAN, IEEE488.2 GPIB,

XGA video output

Max transfer rate

IEEE488.2 GPIB: 500 kbytes/sec

USB (USBTMC-USB488): 3.5 Mbytes/sec

100 Mbps LAN (TCP/IP): 1 Mbytes/sec

Printer compatibility

Current printer support can be found at http://agilent.com/find/InfiniiVision-printers