Performance characteristics, Continued) – Atec Agilent-5000 Series User Manual
Page 18
Performance characteristics
(continued)
Measurement features
Automatic measurements
Measurements are continuously updated. Cursors track last selected measurement.
Voltage
Peak-to-peak, maximum, minimum, average, amplitude, top, base, overshoot, preshoot, RMS,
standard deviation, Ratio (dB)
Time
Frequency, period, + width, – width and duty cycle on any channel. Rise time, fall time, X at max Y
(time at max volts), X at min Y (time at min volts), delay, and phase on oscilloscope channels only.
Counter
Built-in 5-digit frequency counter on any channel. Counts up to the oscilloscope’s bandwidth.
Threshold definition
Variable by percent and absolute value; 10%, 50%, 90% default for time measurements
Cursors
Manually or automatically placed readout of horizontal (X, ΔX, 1/ΔX) and vertical (Y, ΔY). Tracking
Cursors provides an additional mode for cursor positioning beyond the current manual method. When
cursor tracking is enabled, changing a cursor's x-axis position results in the y-axis cursor tracking the
corresponding y-axis (voltage, current, etc.) value. Additionally logic or scope channels
can be displayed as binary or hex values.
Waveform math
f (g(t))
g(t): { 1, 2, 3, 4, 1-2, 1+2, 1x2, 3-4, 3+4, 3x4}
f(t): { 1-2, 1+2, 1x2, 3-4, 3+4, 3x4, FFT(g(t)), differentiate d/dt g(t), integrate ∫ g(t) dt, square
root √g(t) } Where 1,2,3,4 represent analog input channels 1, 2, 3, and 4
Note: Channels 3 and 4 only available on DSO5xx4A models
Measurement Statistics
Statistical data for enabled measurements such as mean, min, max, standard deviation and count
FFT
Points
Up to 10 kpts in precision mode
Source of FFT
1, 2, 1+2, 1-2, 1x2, DSO5xx4A: 3, 4, 3+4, 3-4, 3x4;
where 1, 2, 3, 4 represent the analog channel inputs 1, 2, 3, and 4
Window
Rectangular, flattop, hanning, Blackman Herris
Noise floor
–50 to –90 dB depending on averaging
Amplitude
Display in dBV, dBm at 50 Ω
Frequency resolution
0.05/time per div
Maximum frequency
50/time per div
Storage
Save/recall
10 setups and traces can be saved and recalled using internal non-volatile memory.
Optional secure environment mode ensures setups and traces are stored to internal volatile memory so
data is erased when power is removed. Compliant to NISPOM Chapter 8 requirements.
Storage type and format
USB 1.1 host ports on front and rear panels
Image formats: BMP (8-bit), BMP (24-bit), PNG (24-bit)
Data formats: X and Y (time/voltage) values in CSV format, ASCII XY format, BIN format
Trace/setup formats: Recalled
I/O
Standard ports
USB 2.0 high speed device, two USB 1.1 host ports, 10/100-BaseT LAN, IEEE488.2 GPIB,
XGA video output
Max transfer rate
IEEE488.2 GPIB: 500 kbytes/sec
USB (USBTMC-USB488): 3.5 Mbytes/sec
100 Mbps LAN (TCP/IP): 1 Mbytes/sec
Printer compatibility
Current printer support can be found at http://agilent.com/find/InfiniiVision-printers
18