background image

Chapter 21

633

Safety and Regulatory Information and Specifications

E7495A/B Base Station Test Set Specifications

Safety and Regula

tory In

fo

rmatio

n

a

n

d

Sp
ecification

s

E1 Analyzer Option 710

Error detect:

Code (BPV), FAS, MFAS,CRC-4, Far End Block (FEBE),
Pattern, Fame Slip

Error rate calculation:

Bit-Error-Rate, Error Free Seconds, Errored seconds

Alarm detect:

AIS, TS-16 AIS, FAST DISTANT, MFAS DISTANT

Clock and frame slips:

Clock Slips, Frame slips, Peak Wander, Clock slip rate

Auto configuration:

Automatically detect line code, framing and test pattern

Receive level (line 1 and line 2):

+6 dB DSX to –36 dB DSX or 100 mv p-to-p to
12 v p-to-p

Receive frequency (line 1):

Display receive frequency (± 5 ppm)

Channel access:

Output audio to system

Delay measurement:

Measure delay in unit intervals for “looped-back” signal

Electrical Interface:

Connectors, Rx, Tx:

Output:

Line code:
Impedance:

Input:
Bridge:

Primary and secondary ports

Conforms to ITU-T Rec.G.703

AMI, HDB3
Terminate: 75 ohms ± 5% Bridge:

> 1000 ohms

Terminate: DSX +6 dB to DSX –36 dB
DSX +6 dB to DSX –36 dB

Clock:

Internal:
External:
Recovered:

2.048 MHz

± 5 ppm
± 300 ppm
± 300 ppm

Transmitter and receiver

Framing:

Unframed, PCM-30, PCM-30 with CRC, PCM-31,
PCM-31 with CRC

Channel Formats:

Full E1, 64x1

Table 21-2