Chapter 21

629

Safety and Regulatory Information and Specifications

E7495A/B Base Station Test Set Specifications

Safety and Regula

tory In

fo

rmatio

n

a

n

d

Sp
ecification

s

RF Channel Scanner Option 220 (includes adjacent channel power)

Measurement range

+20 dBm to –125 dBm

>

375 MHz, 10 kHz RBW

(up to +50 dBm with external attenuator)

Frequency readout accuracy:

Timebase accuracy +3 Hz + 1 / (measurement time X duty
cycle)

Frequency range:

10 MHz to 2700 MHz

RF channel power:

± 1 dB (100 to 2500 MHz)

Adjacent channel power accuracy:

± 0.75 dBc

GSM Analyzer Option 230

Frequency range:

100 MHz to 2500 MHz (usable to 10 MHz)

RF channel power:

± 1 dB (0 to –70 dBm)

Phase error floor:

< 2.5 degrees RMS

Phase error accuracy:

< 1 degree RMS, 2 degrees

Phase Error

15 degrees

Frequency error accuracy:

± 40 Hz with external reference

NOTE

Please see the product overview for the latest specifications. This can be found by
visiting the Agilent website at www.agilent.com/find/E7495B, and clicking on the

E7495B Base Station Test Tool Product Overview

” link.

W-CDMA (UMTS) Option 240

Error Vector Magnitude (EVM):
Conditions:

Resolution 0.1%; residual error <6%
Min power at RF input

> –65 dBm,

3GPP test model 4

Code Domain Power Accuracy:

±0.5 dB (for code channel power

>

–25 dB relative to

total power, using test model 1 (with 16 DPCH, 32 DPCH,
and 64 DPCH), test model 2 and test model 3 (with
16 DPCH and 32 DPCH))

Scrambling Code Determination

1 second (in auto mode)

Table 21-2