beautypg.com

Atec Agilent-E7495A User Manual

Page 8

background image

632

Chapter 21

Safety and Regulatory Information and Specifications
E7495A/B Base Station Test Set Specifications

Safety and Regulatory Information

a

n

d

Sp

ecification

s

T1 Analyzer Option 700

Receive level (line 1 and line 2):

+6 dB DSC to –36 dB DSX or 100 mv peak-to-peak to
12 V peak-to-peak

Receive frequency (line 1 and line 2) display receive
frequency (5 ppm) “Loopback” control send CSU or NIU
loop codes CSU/NIU emulation respond to CSU or NIU
loop codes

Electrical interface:

Connectors, Rx, Tx:
Output:

Line build out
Input:

Terminate:
Monitor:
Bridge

Primary and secondary ports
Conforms to TR-TSY-000499, CCITT Rec.G.703
AT&T Pubs CB113, CB119, CB132, CB143
PUB62508 and PUB62411 pulse shape specifications
when terminated in 100 ohms and 0 dB line build-out
is selected
0 dB, –7.5, –15 dB

DSX +6 dB to DSX –36 dB, 100 ohms
DSX –14 dB to DSX –40 dB, 100 ohms
DSX + 6 dB to DSX –36 dB,

> 1000 ohms

Clock:

Internal:
External:
Recovered:

1.544 MHz

± 5 ppm
± 300 ppm
± 300 ppm

Transmitter and receiver:

Framing: Unframed:
Channel formats:

D3 / D4 and ESF
Full T1, 64 X 1

Test patterns:

Error injection type:
Error rate:
Alarm inject type:

QRSS, all Os, 1:7, 2 in 8, 3 in 24, all 1s, T-1-Daly, 55
OCTET

BPV, frame, CRC, pattern (logic)
Single
LOS, LOF, yellow, AIS, idle (CDI)

Table 21-2