beautypg.com

Atec Agilent-E7495A User Manual

Page 10

background image

634

Chapter 21

Safety and Regulatory Information and Specifications
E7495A/B Base Station Test Set Specifications

Safety and Regulatory Information

a

n

d

Sp

ecification

s

Test Patterns:

(True or Inverse, ITU Rec) 2

6

–1 (Q6&Q5), 2

9

–1 (V.52),

2

11

–1 (0.152), 2

15

–1 (0.151) 2

20

–1 (V.57), QRSS,

2

23

–1(0.151), All 0's, 1:7, 1:3, 1:1, All 1's

Error injection

Type:
Error rate:

Code (BPV), FAS, MFAS, CRC-4, Far End Block
(FEBE), Pattern
Single
Alarm generation AIS, TS-16 AIS, FAS DISTANT,
MFAS DISTANT, Loss of signal, Loss of Frame

Table 21-3

E7495A/B Base Station Test Set General Specifications

Display:

Transflective VGA and color LCD

Dimensions

Height:
Width:
Depth:
Weight (without batteries):

11.6”, 295 mm
14.5”, 368 mm
5.3”, 135 mm
20 lbs, 9.1 kg

Power supply:

Internal:

External:
Battery life:

Lithium Ion battery: 10.8 volts, 6.0 Ah (1 NI2040AG
shipped standard, will accept 2 batteries)
DC Input +9 V to +25 V dc (55 Watts)
Approximately 1.5 hour per battery (time varies
depending upon instrument mode)

Table 21-2

E7495A/B Base Station Test Set Option Specifications