Commissioning


The base settings are now completed and the drive can be started:

Start drive

Note

Enter the setpoint.

A) Using the keypad

Set desired output frequency
under C0140.
The min. frequency under
C0010 and the setpoint offset
under C0140 are added!

B) Using the potentiometer via terminals 7, 8,
9

Terminal

E3 E4

34 Hz (2000/min)

HIGH

LOW

67 Hz (4000/min)

LOW

HIGH

12.

C) Enter fixed speed via terminal.

50 Hz (3000/min)

HIGH

HIGH

13. Enable controller.

misc002

Terminal X3/28 = HIGH

14. The drive now operates with the set

frequency. The current output frequency is
indicated under C0050.

Set Disp

SubCode Para H / L

If the drive does not start, press

in addition.

5.4

Shut-down of the pump-motor unit

Shut-down:

1 Set controller inhibit (terminal X3/28 = LOW)
2 Switch off power supply.
3 Close shut-off device in inlet/ pressure line.