Cla-val, Dimensions – Cla-Val 834-05 User Manual
Page 28
CLA-VAL
copyright Cla-Val 2003 Printed in USA Specifications subject to change without notice.
P.O. Box 1325 • Newport Beach, CA 92659-0325 • Phone: 949-722-4800 • Fax: 949-548-5441 • E-mail: [email protected] • Website cla-val.com
©
N-Pressure Switch (SOR)
Housing
Type Contains explosion proof hermetically sealed switch-
ing element. See electrical Service.
Class 1, Groups A,B,C,D Class 11 Groups E, F, G:
Divisions 1&2
. . . . . . . . . . . . . . . . . . .Weathertight NEMA 4 , 4X, IP65
Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .316SS
Wetted Materials
Primary diaphragm . . . . . . . . . . . . . . . . . . . . . . . .316SS
O-ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Viton
Pressure Port . . . . . . . . . . . . . . . . . .1/4 NPT (F) 316SS
Temperature Limits
Process . . . . . . . . . . . . . . . . . .32 to 400ºF (0 to 204ºC)
Ambient . . . . . . . . . . . . . . . . .-40 to 167ºF (-40 to 75ºC)
Notes
1. Other welted materials and pressure port sizes are avail-
able. Consult the factory or the SOR representative in your
area for more information.
2. DC electrical ratings are for resistive loads. DC ratings
are not agency approved or listed but have been verified
by testing or experience.
3. The hermetically sealed switching element capsule is UL
Listed, CSA Certified and SAA Approved as an explosion
proof snap switch
Electrical Connection
1/2 NPT (M): 18” stranded wire leads, 180AWG color-coded
and marked
Electrical Rating
Shipping Weight . . . . . . . . . . .Approximate 1 lb (0.5 kg)
250 VAC
5 amp
30 VDC
5 amp
125 VDC
.5 amp
36.6
1.44
104.9
4.13
Weathertight
external adjustment
cap
35.1
69.9
2.75
1.38
Installation clearance
Pressure port
1 - 1/8" Hex
Nameplate
Agency
approvals &
ratings tag for
switching
elements capsule
1/2 NPT (M)
electrical
connection
1- 1/8" Hex
Factory sealed
electrical leads
Dimensions are for reference only. Contact the factory
for certified drawings for a particular model number.
Linear =
mm
in.
Dimensions
Weathertight gasket
and cap retainer
Agency
UL Listed
CSA Certified
SAA
Approved
Hazardous Location Conditions
Class 1, Group A,B,C and D
Class 11, Group E, F & G;
Division 1 & 2
Ex s IIC T6 for class 1, Zone 1
DIP Type B 80ºC Class II, Div. 1&2
Design and specification subject to change without notice.