beautypg.com

Cla-val – Cla-Val 390-07/3690-07 User Manual

Page 18

background image

When Ordering, Please Specify

1. Catalog No. CRD-33 (Direct Sensing) or CRA-33 (Remote Sensing)

2. Materials - Pilot Control - Wetted Parts

PO Box 1325 Newport Beach CA 92659-0325

Phone: 949-722-4800

Fax: 949-548-5441

CLA-VAL

CLA-VAL CANADA

CLA-VAL EUROPE

4687 Christie Drive
Beamsville, Ontario
Canada L0R 1B4
Phone: 905-563-4963
Fax: 905-563-4040

Chemin dés Mesanges 1
CH-1032 Romanel/
Lausanne, Switzerland
Phone: 41-21-643-15-55
Fax: 41-21-643-15-50

©

COPYRIGHT CLA-VAL 2011 Printed in USA

Specifications subject to change without notice.

www.cla-val.com

Adjustment Ranges

2 to 30

psi

15 to 75 psi
20 to 105 psi
30 to 300 psi

End Connection

3/8" NPT

Temperature Range

Water: to 180°F

Materials

Pilot Control: Bronze ASTM B62

Trim:Stainless Steel Type 303

Rubber:Buna-N

®

Synthetic Rubber

Available with optional Stainless Steel or Monel materials
at additional cost. Consult factory for details.
Note: Available with remote sensing control (specify CRA-33)

Note: Total Shipping Weight: 8 Lbs.

Represented By:

E-CRD-33 and CRA-33 (R-9/2011)

CRD-33 and CRA-33 Purchase Specifications

The Electronic Actuated Pressure Reducing Pilot Control shall have an integral hydraulic pilot and electronic controller contained in a
IP-68 rated submersible enclosure to provide interface between remote telemetry and valve set-point control. It will compare a remote
analog command signal with an internal position sensor signal and adjust the hydraulic pilot control spring mechanism to a new set-point
position. Remote analog signal input shall be isolated and reverse polarity protected. 4-20 mA actuator position feedback output shall be
supplied standard. A second command control input shall be from dry-contact switch closure for clockwise or counter clockwise actuator rota-
tion. Assembly shall be factory calibrated to the spring range listed below.
If power fails, the control pilot valve shall continue to control main valve to last set-point command. If the Remote Set-Point signal is lost the actu-
ator shall be programmable to go to either the 4mA, Last, or 20mA command set-point. No mechanical adjustments shall be necessary
to the actuator. The low and high position range adjustment shall be accomplished only with valve manufacturer's components and
instructions to be supplied in a separate kit. The assembly shall be supplied with 30 feet of cable.

The Electronic Actuated Pressure Reducing Pilot Control shall be Cla-Val Model CRD-33 or CRA-33 as manufactured by Cla-Val, Newport Beach, CA.

Pilot Control Subassembly Specifications

CRD-33 and CRA-33 Electronic Actuator Specifications

USB connection cable required when changing range

parameters or restoring range parameters after servicing

pilot control subassembly.

Options:

Re-ranging software - free download from www.cla-val.com.
Ranging software makes it easy to set low (4mA) and
high (20mA) set-point limits.

Supply Power Input:

12V to 24V DC24V DC
No Load draw: 50 mA
Max. Load draw: 250 mA

Remote Command Inputs:

4-20mA, analog signal

(isolated and reverse-polarity
protected)

Dry contact closure (CW/CCW)

Position Feedback Signal: 4-20 mA

Alarm Output:

Dry-contact closure (High/Low)

Speed of Rotation:

Adjustable On/Off time, max 6 rpm

Diagnostic:

LED Indicator

Loss of Power:

Actuator will remain in last commanded
position.

Loss of Signal Position:

Programmable - 4 mA, Last, or 20 mA

Electrical Connections:

Single, 30 feet of permanently attached
cable with color-coded power supply
and signal wires

Mechanical Specifications:

Environmental

Protection Class:

IP-68 (Temporary submersible)

Ambient Temperature: 15° to 150° F (-10° to 65° C)

Materials

Enclosure and Bracket:

Anodized Aluminum

Coupling Assembly:

Stainless Steel

Gear Train:

Stainless Steel, permanently lubricated