beautypg.com

10” pdpf high elevations – Gotham 10 PDPF High Elevations Baffle SpecSheet User Manual

Page 3

background image

GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com

© 2008-2012 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 11/19/12. Specifications subject to change without notice.

PAGE 3 OF 3

PDPF-10-XBAFFLE

PDPF 2/42TRT 10CB

(2) CF42DT/E/IN/835, 3200 LUMENS PER LAMP, 1.3 S/MH, TEST NO. LTL9621

PDPF 2/32TRT 10CB

(2) CF32DT/E/IN/835, 2400 LUMENS PER LAMP, 1.3 S/MH, TEST NO. LTL9622

PDPF 3/32TRT 10CB

(3) CF32DT/E/IN/835, 2400 LUMENS PER LAMP, 1.2 S/MH, TEST NO. LTL9662

PH

OTO
M

ET

RY

Distribution Curve

Distribution Data

Output Data

Coefficient of Utilization

Illuminance: Single Luminaire 30” Above Floor

10” PDPF

High Elevations

®

Performance Downlight Cross Baffle Pendant, Horizontal Triple-Tube Lamp

PDPF 3/42TRT 10CB

(3) CF42DT/E/IN/835, 3200 LUMENS PER LAMP, 1.2 S/MH, TEST NO. LTL9663

Zone

Lumens % Lamp

0° - 30°
0° - 40°
0° - 60°
0° - 90°

90° - 180°

0° - 180°

1735.3
2627.2
3161.6
3173.5

0.0

3173.5

27.1
41.1
49.4
49.6

0.0

*49.6

*E

fficiency

10°

20°

30°

40°

50°

60°

70°

80°

90°

400

800

1200

1600

2000

pf
pc
pw

20%

80%

70%

50%

50% 30% 50% 30% 50% 30%

1
2
3
4
5
6
7
8
9

10

.54
.50
.46
.43
.39
.36
.34
.31
.29
.27

.53
.48
.43
.39
.36
.33
.30
.28
.26
.24

.53
.49
.45
.42
.39
.36
.33
.31
.29
.27

.52
.47
.43
.39
.36
.33
.30
.28
.26
.24

.51
.48
.44
.41
.38
.35
.33
.30
.28
.27

.50
.46
.42
.38
.35
.32
.30
.28
.26
.24

F rom 0°

Ave

Lumens

0
5

15
25
35
45
55
65
75
85
90

1958
2067
2193
2013
1463

633

67

8
3
0
0

200
613
921
892
457

78

9
3
0

50% beam angle

66.0°

10% beam angle

91.3°

Mount
height

Inital fc

at beam

center

B eam

diameter

fc at

beam

edge

B eam

diameter

fc at

beam

edge

8

10
12
14
16

64.7
34.8
21.7
14.8
10.7

7.1
9.7

12.3
14.9
17.5

32.4
17.4
10.8

7.4
5.4

11.3
15.4
19.4
23.5
27.6

6.5
3.5
2.2
1.5
1.1

Zone

Lumens % Lamp

0° - 30°
0° - 40°
0° - 60°
0° - 90°

90° - 180°

0° - 180°

1280.4
1938.0
2334.6
2343.5

0.0

2343.5

26.7
40.4
48.6
48.8

0.0

*48.8

*E

fficiency

10°

20°

30°

40°

50°

60°

70°

80°

90°

300

600

900

1200

1500

pf
pc
pw

20%

80%

70%

50%

50% 30% 50% 30% 50% 30%

1
2
3
4
5
6
7
8
9

10

.54
.49
.45
.42
.39
.36
.33
.31
.29
.27

.52
.47
.43
.39
.35
.32
.30
.27
.25
.24

.53
.48
.45
.41
.38
.35
.33
.30
.28
.27

.51
.46
.42
.38
.35
.32
.30
.27
.25
.23

.51
.47
.43
.40
.37
.34
.32
.30
.28
.26

.50
.45
.41
.38
.35
.32
.29
.27
.25
.23

F rom 0°

Ave

Lumens

0
5

15
25
35
45
55
65
75
85
90

1426
1491
1588
1523
1067

396

61

6
1
0
0

144
445
691
658
325

72

7
2
0

50% beam angle

66.1°

10% beam angle

89.8°

Mount
height

Inital fc

at beam

center

B eam

diameter

fc at

beam

edge

B eam

diameter

fc at

beam

edge

8

10
12
14
16

47.1
25.4
15.8
10.8

7.8

7.2
9.8

12.4
15.0
17.6

23.6
12.7

7.9
5.4
3.9

11.0
15.0
18.9
22.9
26.9

4.7
2.5
1.6
1.1
0.8

Zone

Lumens % Lamp

0° - 30°
0° - 40°
0° - 60°
0° - 90°

90° - 180°

0° - 180°

1687.3
2548.8
3001.7
3012.4

0.0

3012.4

23.4
35.4
41.7
41.8

0.0

*41.8

*E

fficiency

10°

20°

30°

40°

50°

60°

70°

80°

90°

400

800

1200

1600

2000

pf
pc
pw

20%

80%

70%

50%

50% 30% 50% 30% 50% 30%

1
2
3
4
5
6
7
8
9

10

.46
.42
.39
.36
.33
.31
.29
.27
.25
.23

.45
.41
.37
.34
.31
.28
.26
.24
.22
.21

.45
.42
.38
.36
.33
.31
.28
.26
.25
.23

.44
.40
.36
.33
.30
.28
.26
.24
.22
.21

.43
.40
.37
.35
.32
.30
.28
.26
.24
.23

.43
.39
.36
.33
.30
.28
.25
.24
.22
.20

F rom 0°

Ave

Lumens

0
5

15
25
35
45
55
65
75
85
90

2067
2059
2150
1939
1402

506

40

7
2
0
0

195
605
887
862
402

51

8
2
0

50% beam angle

62.5°

10% beam angle

88.8°

Mount
height

Inital fc

at beam

center

B eam

diameter

fc at

beam

edge

B eam

diameter

fc at

beam

edge

8

10
12
14
16

68.3
36.7
22.9
15.6
11.3

6.7
9.1

11.5
14.0
16.4

34.2
18.4
11.5

7.8
5.7

10.8
14.7
18.6
22.5
26.4

6.8
3.7
2.3
1.6
1.1

Zone

Lumens % Lamp

0° - 30°
0° - 40°
0° - 60°
0° - 90°

90° - 180°

0° - 180°

2531.6
3764.2
4407.1
4423.0

0.0

4423.0

26.4
39.2
45.9
46.1

0.0

*46.1

*E

fficiency

10°

20°

30°

40°

50°

60°

70°

80°

90°

600

1200

1800

2400

3000

pf
pc
pw

20%

80%

70%

50%

50% 30% 50% 30% 50% 30%

1
2
3
4
5
6
7
8
9

10

.51
.47
.43
.40
.37
.34
.32
.30
.28
.26

.49
.45
.41
.37
.34
.31
.29
.27
.25
.23

.50
.46
.42
.39
.36
.34
.31
.29
.27
.26

.49
.44
.40
.37
.34
.31
.29
.26
.25
.23

.48
.44
.41
.38
.36
.33
.31
.29
.27
.25

.47
.43
.39
.36
.33
.31
.28
.26
.24
.23

F rom 0°

Ave

Lumens

0
5

15
25
35
45
55
65
75
85
90

3126
3177
3262
2849
2030

711

64
11

3
0
0

304
914

1313
1233

564

79
12

4
1

50% beam angle

61.5°

10% beam angle

88.0°

Mount
height

Inital fc

at beam

center

B eam

diameter

fc at

beam

edge

B eam

diameter

fc at

beam

edge

8

10
12
14
16

103.3

55.6
34.6
23.6
17.2

6.5
8.9

11.3
13.7
16.1

51.7
27.8
17.3
11.8

8.6

10.6
14.5
18.4
22.2
26.1

10.3

5.6
3.5
2.4
1.7

PHOTOMETRY NOTES

Tested to current IES and NEMA standards under stabilized laboratory conditions.

Actual performance may differ as a result of end-user environment and application.

Consult factory or IES file for microgroove baffle, black cone or other photometric reports.