Extron • System 4

xi

Switcher Series • User’s Manual

Projector Communication Extension Cables

Connectors

Part #

CC 50' (50 ft.)

15/HD/M to 9/D/F

26-305-01

CC 50' Type II (50 ft.)

15/D/M to 15/D/F

26-323-01

CC 100' (100 ft.)

15/HD/M to 9/D/F

26-305-02

CC 100' Type II (100 ft.)

15/D/M to 15/D/F

26-323-02

CC 200' (200 ft.)

15/HD/M to 9/D/F

26-305-03

CC 200' Type II (200 ft.)

15/D/M to 15/D/F

26-323-03

S-Video Adapter Cables
S-VHS 6' (male-to-male, 6 feet)

26-316-02

S-VHS M20' (male-to-male, 20 feet)

26-316-01

S-VHS BNC (male-to-male, S-video to BNC, 6")

26-353-01

Connectors
Captive Screw Phoenix Connectors (6-pin, Audio)

10-163-01

Documentation
System 4

xi

User’s Manual

68-162-01

System 4

xi

Label

33-151-01

Changing the Main Fuse

_________ The Main Fuse is located on the Power Supply board. To replace the fuse,

remove the AC Power cord and remove the top cover of the System 4

xi

(procedure on page 2-3).

The picture below shows the left-rear corner of the System 4

xi

chassis. Locate

the fuse on the Power Supply board.

Remove the fuse from its holder and test it with an ohm meter or other testing
device. Replace a bad fuse with a 2 amp, 250v fuse.

If the fuse is not bad, and the unit has no indication of having power, call Extron
for instructions on service.

Figure B-2. Locate the Fuse on the Power Supply.

B-2