beautypg.com

Looping the system 4 xi with other switchers – Extron Electronics System 4xi Series User Manual

Page 38

background image

Extron • System 4

xi

Switcher Series • User’s Manual

Chapter 4 • Connecting Multiple Switchers

Looping the System 4

xi

with Other Switchers

The System 4

xi

can be interconnected, or “looped” with other switchers to allow

for a greater number of inputs to be switched to the projector. With each of these
configurations, the System 4

xi

acts as the “Master”, to communicate with the

projector and supply the video signal. The switcher that provides input to the
System 4

xi

is the “Slave”. If two switchers are looped with the System 4

xi

, the

second switcher is a “Slave” to the first, and the first is a “Slave” to the
System 4

xi

.

• The slave switcher is always connected to the highest master input (input #4

on a System 4

xi

, input #10 on a System 10 and input #8 on a System 8, etc.).

• Input numbering always starts at input #1 of the System 4

xi

and input #4 will

become the first input from the “slave” switcher.

• The System 4

xi

cannot be used as a slave switcher.

• The only switchers that can be looped with the System 4

xi

are:

Extron’s SW4 ARMX, SW6 ARMX, System 8 P

LUS

and System 10 P

LUS

.

• In any master/slave arrangement, the System 4

xi

acts as if it is one large

switcher. That is, each slave input can be selected and set up from the
System 4

xi

Front Panel. Any Slave input can be configured for any signal

type.
For example, a System 4LD

xi

with a System 8 P

LUS

as a slave is seen by PC

software as a line-doubling, 11-input switcher.

Input Channel Addressing

The System 4

xi

must be set up to recognize input that is from another switcher

unit. The Front Panel operation in Chapter 3 explains how this is done. In a
master/slave configuration, input channel numbers of 4 or higher are translated
and sent to the appropriate slave input number. For example, selecting input #9
will select input #4 on the System 4

xi

, and then tell the slave switcher to select its

input #6. See shaded table entry below.

Channel

Sys4

SW4

SW6

SW8+ SW10+

Multiple SW8+/SW10+

Ch #1

Ch #1

Ch #2

Ch #2

Ch #3

Ch #3

Ch #4

Ch #4

Ch #1

Ch #1

Ch #1

Ch #1

Ch #1 (1st SW10)

Ch #5

Ch #4

Ch #2

Ch #2

Ch #2

Ch #2

Ch #2

Ch #6

Ch #4

Ch #3

Ch #3

Ch #3

Ch #3

Ch #3

Ch #7

Ch #4

Ch #4

Ch #4

Ch #4

Ch #4

Ch #4

Ch #8

Ch #4

Ch #5

Ch #5

Ch #5

Ch #5

Ch #9

Ch #4

Ch #6

Ch #6

Ch #6

Ch #6

Ch #10

Ch #4

Ch #7

Ch #7

Ch #7

Ch #11

Ch #4

Ch #8

Ch #8

Ch #8

Ch #12

Ch #4

Ch #9

Ch #9

Ch #13

Ch #4

Ch #10

Ch #10

Ch #14

Ch #4

Ch #2 (2nd SW10)

Ch #15-22*

Ch #4

Ch #3 - 10

* Channel numbers continue if multiple switchers are used as slaves. The
highest number of channels is 22, using two System 10 P

LUS

units as slaves.

The following pages show configurations for looping the System 4

xi

with other

Extron-approved switchers. Looping the System 4

xi

will not work with all

switchers; call Extron Electronics if you have any questions.

4-1