beautypg.com

Extron Electronics System 4xi Series User Manual

Page 43

background image

Extron • System 4

xi

Switcher Series • User’s Manual

Chapter 4 • Connecting Multiple Switchers

System 8/10 P

LUS

Switch Settings

From the front access panel on the System 8/10 P

LUS

, do the following:

1. On DIP switch block SW15, set switches #6 and #8 ON.

2. Set rotary switch RS4 to the “0” position.

On the rear panel of the System 8/10 P

LUS

, do the following:

3. Set the Norm/VLB switch on the back of the 8/10 P

LUS

set to “Norm”.

4. Set the Address switches for “master”. (If looping two 8/10 P

LUS

systems to

the System 4

xi

, the second one must be set as a “slave”.)

5. Set the Video/RGBS switches to match the type of video to be used by each

input and do the configuration setup.

Go to page 4-7 to configure the master/

slave as a system.

_______ Refer to the System 8/10

P

LUS

User’s Manual for

other switch settings.

Figure 4-6. System 8/10 Plus Setup Switches

4-6

Figure 4-5. System 8/10 Plus Front Access Panel Switches