Factory defaults, Preliminar y, Serial communication, cont’d – Extron Electronics PVS 204SA User Guide User Manual
Page 38
Serial Communication, cont’d
PVS 204SA • Serial Communication
4-4
PRELIMINAR
Y
X$
= 0 – 14, bass and treble adjustment range
(+/- 10.5 dB: 1.5 dB increments/decrements),
default = 7 = 0 dB
Value (dB)
0
-10.5
1
-9
2
-7.5
3
-6
4
-4.5
5
-3
6
-1.5
7
0
8
+1.5
9
+3
10
+4.5
11
+6
12
+7.5
13
+9
14
+10.5
X%
= -10.5 to +10.5, bass and treble, readout in dB
X^
= 0 – 100, volume, default = 50
X&
= 0 – 24, input gain adjustment range, default = 0, in dB
X*
= 1 – 42, input attenuation adjustment range, in dB
X(
= -18 to + 24, input gain and attenuation readout, in dB
X1)
= -10 through +10, power amp gain readout, in dB
X1!
= Status
1 = single mode
2 = separate switcher mode
X1@
= 0 thru 20, power amp attenuation adjustment range,
(where 0 = -10 dB, 20 = + 10 dB, in 1 dB increments/decrements)
X1#
= Status
0 = not present/malfunction
1 = present/OK
X1$
= Internal temperature
X1%
= Group
1 = RGB/VGA
2 = composite video/vid
X2!
= Version (X.XX)
X2@
= RGB delay in 0.5 second steps;
0 = 0 seconds, 1 = 0.5 seconds, ...10 = 5.0 seconds
Factory defaults
Input Audio Gain
X&
= 0
Power Amp Gain
X1)
= 0
Volume
X^
= 50
Bass Level
X$
= 7
Treble Level
X$
= 7
Switcher Mode
X1!
= 1
Audio Output
X@
= 2
Clip Limiter
X#
= 0
Loudness
X#
= 0