beautypg.com

Factory defaults, Preliminar y, Serial communication, cont’d – Extron Electronics PVS 204SA User Guide User Manual

Page 38

background image

Serial Communication, cont’d

PVS 204SA • Serial Communication

4-4

PRELIMINAR

Y

X$

= 0 – 14, bass and treble adjustment range

(+/- 10.5 dB: 1.5 dB increments/decrements),

default = 7 = 0 dB

Value (dB)

0

-10.5

1

-9

2

-7.5

3

-6

4

-4.5

5

-3

6

-1.5

7

0

8

+1.5

9

+3

10

+4.5

11

+6

12

+7.5

13

+9

14

+10.5

X%

= -10.5 to +10.5, bass and treble, readout in dB

X^

= 0 – 100, volume, default = 50

X&

= 0 – 24, input gain adjustment range, default = 0, in dB

X*

= 1 – 42, input attenuation adjustment range, in dB

X(

= -18 to + 24, input gain and attenuation readout, in dB

X1)

= -10 through +10, power amp gain readout, in dB

X1!

= Status

1 = single mode

2 = separate switcher mode

X1@

= 0 thru 20, power amp attenuation adjustment range,

(where 0 = -10 dB, 20 = + 10 dB, in 1 dB increments/decrements)

X1#

= Status

0 = not present/malfunction

1 = present/OK

X1$

= Internal temperature

X1%

= Group

1 = RGB/VGA

2 = composite video/vid

X2!

= Version (X.XX)

X2@

= RGB delay in 0.5 second steps;

0 = 0 seconds, 1 = 0.5 seconds, ...10 = 5.0 seconds

Factory defaults

Input Audio Gain

X&

= 0

Power Amp Gain

X1)

= 0

Volume

X^

= 50

Bass Level

X$

= 7

Treble Level

X$

= 7

Switcher Mode

X1!

= 1

Audio Output

X@

= 2

Clip Limiter

X#

= 0

Loudness

X#

= 0