Rs-232 programmer’s guide, Host-to-pvs communications, Pvs-initiated messages – Extron Electronics PVS 204SA User Guide User Manual
Page 36: Eble have been set at 0 db. see chapter 4, “serial, Communication, Ol, see chapter 4, “serial communication, Preliminar y, Serial communication
PVS 204SA • Serial Communication
4-2
Serial Communication
PRELIMINAR
Y
The PVS 204SA switcher can be remotely set up and controlled via a host
computer or other device (such as a control system) attached to the rear panel
RS-232/MLC/IR port. Alternatively, the switcher can be controlled by an optional
MediaLink Controller (MLC) (connected to the same port) or by an RS-232 device
acting through the MLC. The control device (host) can use either Extron’s Simple
Instruction Set (SIS
™
) commands or the Global Configurator
(GC2) program for Windows. For details on use and setup
of a system that includes a MediaLink Controller, refer
to the MediaLink Controller user’s manual.
Switcher protocol:
• 9600 baud • 1 stop bit • no parity • no flow control
RS-232/MLC/IR connector pin assignments:
N
Configuration can also be completed by
connecting a 2.5 mm stereo mini cable
(part # 70-335-01) to the 2.5 mm jack (port)
on the front panel. This port has the same
protocol as the RS-232 connector on the rear panel.
6 feet
5
1
9
6
Sleeve (Gnd)
Ring
Tip
9-pin D
Connection
TRS Plug
Pin 2
Computer's RX line
Tip
Pin 3
Computer's TX line
Ring
Pin 5
Computer's signal ground
Sleeve
Figure 4-1 — Pin out diagram for 2.5 mm mini cable TRS plug when
connecting to the front panel Config port
N
Firmware updates can be made only via the front panel Config port.
RS-232 Programmer’s Guide
Host-to-PVS communications
SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command sequence. When the PVS switcher determines
that a command is valid, it executes the command and sends a response to the host
device. All responses from the switcher to the host end with a carriage return and
a line feed (CR/LF = ]), which signals the end of the response character string. A
string is one or more characters.
PVS-initiated messages
When a local event such as a front panel selection or adjustment takes place, the
PVS responds by sending a message to the host. No response is required from the
host. The PVS-initiated messages are listed here (underlined).
© Copyright 2006, Extron Electronics, PVS 204SA, V1.xx Chn x
The PVS sends the copyright messages when it first powers on. V1.xx is the
firmware version number.
Chn X! ] (where X! is the input number)
The PVS sends this response when an input is switched.
RS-232/MLC/IR
Tx Rx IR +12V
A B C
E
D
(A) Transmit (Tx)
(B) Receive (Rx)
(C)
IR in
(E) +12 VDC out