beautypg.com

Extron Electronics LANCIAxi User Guide User Manual

Page 23

background image

Extron • SENTOSA

xi

LQ & LANCIA

xi

LD • User’s Manual

RS-232/REMOTE Control

Page 3-2

COMMAND/RESPONSE TABLE
Definitions and Abbreviations:

= CR/LF

· = space

= 1 or 2 (Input #)

= 1 – 127

= 0 or 1, 0 = OFF, 1 = ON

= Input type (T), 0 = no input, 1 = NTSC 3.58, 2 = PAL, 3 = NTSC 4.43, 4 = SECAM

= Software version x.xx

= 1 – 63

COMMAND

RESPONSE

Example Commands and Responses

ASCII HEX

to Host

Command Description

Command

Response

Action/Explanation

!

h

21

h

C

Select input channel (C)

2!

C2

Select Input channel #2

F

7C

h

Frz1

Freeze ON (ASCII F or | accepted)

F

Frz1

Freeze (Frame) Video

f

7E

h

Frz0

Freeze OFF (ASCII f or ~ accepted)

f

Frz0

Release Freeze Mode

i

69

h

(Same as I below)

Information request

i

C2·T1·Col65·Tin70·Con100·Hph39·Frz0

I

49

h

C

·T

·Col

·Tin

·Con

·Hph

·Frz

I

C2·T1·Col65·Tin70·Con100·Hph39·Frz0

n

6E

h

(Same as N below)

Request for part number

n

N60-213-01

60-213-01 = Lancia

N

4E

h

N60-213-01

Request for part number

N

N60-229-01

60-229-01 = Sentosa

q

71

h

(Same as Q below)

Query software version

q

QVER·1.23

(1.23 is example only)

Q

51

h

QVER·

Query software version

Q

QVER·1.23

Software version 1.23

C

h

43

h

Col

Set color value (Col) to

25C

Col25

Color value to 25

{C

7B

h

43

h

Col

Increment color value

{C

Col26

Color value + 1

}C

7D

h

43

h

Col

Decrement color value

}C

Col25

Color value – 1

T

h

54

h

Tin

Set tint value (Tin) to

32T

Tin32

Tint value to 32

{T

7B

h

54

h

Tin

Increment tint value

{T

Tin33

Tint value + 1

}T

7D

h

54

h

Tin

Decrement tint value

}T

Tin32

Tint value – 1

^

h

5E

h

Con

Set contrast value (Con)to

99^

Con99

Contrast value to 99

{^

7B

h

5E

h

Con

Increment contrast value

{^

Con100

Contrast value + 1

}^

7D

h

5E

h

Con

Decrement contrast value

}^

Con99

Contrast value – 1

H

h

48

h

Hph

Set horizontal phase value (Hph) to

39H

Hph39

Set H. Phase Value to 39

{H

7B

h

48

h

Hph

Increment Hph value

{H

Hph40

Horiz. Phase Value + 1

}H

7D

h

48

h

Hph

Decrement Hph value

}H

Hph39

Horiz. Phase Value – 1

Exx

Error Response

see “Error Responses” – next page