beautypg.com

Edid minder configuration, Twisted pair cable termination – Extron Electronics MTP T 15HD A User Guide User Manual

Page 20

background image

MTP T 15HD A Architectural Series • Installation

14

EDID Minder Configuration

The MTP T 15HD A D unit supports emulation of factory-installed EDID information through
EDID Minder.

To use factory-installed EDID information:

1.

If you have not already done so, connect the source device to the MTP 15HD
transmitter. Do not power on the source device at this time.

2.

Set the rear panel DIP switch (see

d

on page

11

) to the required frequency (50 or

60 Hz).

NOTE: When the rotary dial (see

e

on page

11

) is set to position 0, the frequency

DIP switch position is ignored.

3.

Set the rotary dial (see

e

on page

11

) to the required position (see figure 15 for specific

EDID and its corresponding rotary switch position).

Positions 1 through F are factory installed. Position 0 is not used.

Rotary Switch

Position

Resolution

0

Not used

1

800x600

2

1024x768 (default)

3

1280x720

4

1280x768

5

1280x800

6

1280x1024

7

1360x768

8

1366x768

9

1400x1050

A

1400x900

B

1600x900

C

1600x1200

D

1680x1050

E

1920x1080

F

1920x1200

Figure 15.

EDID Settings Table