Local, Audio output volume, Sis commands for details – Extron Electronics MTP SW6 User Guide User Manual
Page 29

Command
ASCII Command
(host to unit)
Response
(unit to host)
Additional description
Local audio output volume
Set the local audio output
volume to a specific value
X1@
V
Vol
X1@]
Example:
50V
Vol50
]
Set the output volume to 50%.
Increment volume
+V
Vol
X1@]
Increment volume by 1%.
Example:
+V
Vol51
]
Decrement volume
-V
Vol
X1@]
Decrement volume by 1%
Read output volume
V
X1@]
Audio or RS-232 mute commands
Audio or RS-232 mute
1Z
Amt1
]
Mute (silence) the audio or RS-232 output.
Audio or RS-232 unmute
0Z
Amt0
]
Unmute the audio or RS-232 output (audio on).
Read audio/RS-232 mute
status
Z
X1#]
1 = mute on, 0 = mute off.
Switch mode
Set normal (manual)
switch mode
1#
F1
]
The user selects an input manually, from the front
panel or under remote control.
Set auto switch mode
2#
F2
]
The switcher automatically switches to the highest
numbered input with signals present. Manual input
selection is disabled.
Front panel lock (executive mode)
Lock the front panel
1X
Exe1
]
Lock the front panel level, peaking, and skew
functions. The switch mode (auto or manual) cannot
be changed. Input selection is still available.
Unlock the front panel
0X
Exe0
]
All front panel functions are available.
View lock status
X
X1#]
Resets
Reset all video level and
peaking adjustments
E
ZT
}
Zpt
]
Clear all video level and peaking adjustments to their
default (0) values.
Reset all skew
adjustments
E
ZK
}
Zpk
]
Clear all input and output skew values to 0 ns.
Reset audio input levels
E
ZA
}
Zpa
]
Reset all audio input levels (gain and attenuation) to
0 dB.
Reset audio output levels
E
ZV
}
Zpv
]
Reset the audio output level (volume) to 100% (no
attenuation.
Reset whole switcher
E
ZXXX
}
Zpx
]
Reset all level and peaking, skew, audio input gain
and attenuation values to 0. Reset output volume to
100% ( no attenuation).
Information requests
Information request
I
V
X!
•A
X!
•F
X1$
•Vmt
X1#
•Amt
X1#
•Exe
X1#]
V (selected video input) • A (selected audio input) •
F (switch mode) • Vmt (video mute — not supported
by this switcher) • Amt (audio mute status) • Exe
(front panel lock).
Request part number
N
68-928-01
]
Query controller version
Q
X1%]
Example:
Q
1.23
]
The factory-installed firmware version is 1.23 (sample
value only).
Request system threshold
status
42S
X@]
NOTE:
X!
= Input number
1-6
X@
= Threshold
0 = outside threshold 1 = within threshold
X1@
= Volume adjustment range
0 - 100
X1#
= Mute, front panel lock
0 = off
1 = on
X1$
= Switch mode
1 = normal (manual) 2 = auto
X1%
= Firmware version
v.vv
Command/response table for SIS commands (continued)
MTP SW6 • Remote Control
25