The switcher can be remotely controlled via its rear panel Remote connector (Figure 13).
Remote control devices can be:

A host device such as a computer or control system

A device such as an Extron IR 102 Universal remote control kit

A contact closure device such as an Extron KP 6 Keypad Control

REMOTE

PIN RS-232

Contact

Closure Function

1

In #1

Input #1

Input #2

Input #3
Input #4
Input #5
Input #6

2

TX

Transmit data

3

RX

Receive data

4

In #2

5

Gnd

Gnd

Ground

6

In #3

7

In #4

8

In #5

9

In #6

Figure 13.

Remote connector pinout

NOTES: • The cable used to connect the Remote port to a computer, control

system, contact closure device, or IR control kit may need to be modified
by removing pins or cutting wires. If unneeded pins are connected, the
switcher may hang up.

• For RS-232, Windows-based program, and IR control, use a control cable

with only pins 2, 3, and 5 connected. Otherwise, either cut the wires to the
other pins in hard-shelled connectors or remove the unneeded pins from
molded plugs

• See

Simple Instruction Set Control

for definitions of the SIS commands.

• See

Windows-Based Program Control

for details on how to install and

use the control software.

• For contact closure, use a control cable with pins 2 and 3 disconnected.

Otherwise, either cut the wires to these pins in hard-shelled connectors or
remove these pins from molded plugs. See

Contact Closure Control

for

information on how to make a remote contact closure device.