MPX 423 A • SIS Programming and Control

PRELIMINAR

Y

• If the unit is on, it sends the boot and copyright messages when you first open

a Telnet connection to the unit. You can see the day of the week, date, and time

if the unit is connected via Telnet, but not via RS-232. If you are using a Telnet

connection, the copyright message, date, and time are followed by a password

prompt (if set).

Password information

The “

]

Password:” prompt requires a password (administrator level or user level)

followed by a carriage return.
If the correct password is entered, the unit responds with “

]

Login Administrator

]

” or “

]

Login User

]

”, depending on password entered. If passwords are the

same for both administrator and user, the unit defaults to administrator privileges.

Error responses

If the MPX 423 A is unable to execute a command, it returns an error response to the

host. The error response codes and their descriptions are as follows:
E01 – Invalid input channel number (the number is too large)

E10 – Invalid command

E12 – Invalid output number / invalid port number

E13 – Invalid value (the number is out of range/too large)

E14 – Not valid for this configuration

E17 – System timed out

E22 – Busy

E23 – Checksum error (for file uploads)

E24 – Privilege violation (Ethernet, Extron software only). User privileges have

access to ALL view and read commands, and the following:

create ties

set RGB and audio mutes

Exception: User cannot read Admin password

E25 – Device is not present

E26 – Maximum number of connections has been exceeded

E27 – Invalid event number

E28 – Bad filename or file not found

Error response references

The following superscripted numbers are used within the command descriptions

on the following pages to identify commands that may respond as shown:

14

= Commands that give an E14 (not valid for this configuration) response if the

unit’s current configuration doesn’t support that command

22

= Commands that yield an E22 (busy) response.

24

= Commands that give an E24 (privilege violation) response if you are not

logged in at the administrator level.

27

= Commands that may yield an E27 (invalid event number) response.

28

= Commands that may give an E28 (file not found) response.

Copyright information

The following copyright message is initiated by the MPX 423 A matrix switcher at

power-up (for an RS-232 connection):
(c) Copyright 2007, Extron Electronics, MPX 423A, Vx.xx, 60-683-01
Vx.xx = the firmware version number.