Unit-initiated Messages
When a local event, such as an equipment power-up, occurs, the unit responds by sending a
message to the host. The unit-initiated messages are listed below:
(c) Copyright 20nn, Extron Electronics FOXBOX Tx HDMI, Vx.xx, 60-1174-xx]]
- or -
(c) Copyright 20nn, Extron Electronics FOXBOX Rx HDMI, Vx.xx, 60-1174-xx]]
The connected unit issues the appropriate copyright message (above) when it first powers
on. Vx.xx is the firmware version number; 60-1174-xx is the part number of the connected
unit.
Reconfig]
The unit sends the Reconfig message whenever the video input signal to the transmitter is
changed.
1Lnk
X1!
•2Lnk
X1!
•Vid
X1!
•Aud
X1!
]
The unit sends the status message whenever a change in the fiber link and video connection
occurs.
EmbedAud
X1%
]
The unit sends the Embedded audio message whenever a change in the position of the
receiver rear panel HDMI Audio switch occurs.
Error Responses
When the unit receives a valid SIS command, it executes the command and sends a response
to the host device. If the unit is unable to execute the command because the command is
invalid or it contains invalid parameters, the unit returns an error response to the host. The
error response codes are:
E10 - Invalid command
E11 - Invalid preset number
E13 - Invalid parameter
E14 - Invalid command for this configuration
Using the Command/Response Tables
The command/response table begins on the next page. Either uppercase or lower case letters
are acceptable in the command field except where indicated for the audio level (gain and
attenuation) commands. Symbols are used throughout the table to represent variables in
the command/response fields. Command and response examples are shown throughout the
table. The ASCII to HEX conversion table below is for use with the command/response table.
ASCII to Hex Conversion Table
•
Space
FOXBOX Tx/Rx HDMI • Remote Control
19