FOX SW8 • Remote Control
10
Error Responses
When the unit receives a valid SIS command, it executes the command and sends a
response to the host device. If the unit is unable to execute the command because the
command is invalid or it contains invalid parameters, the unit returns an error response to
the host. The error response codes are:
E10 — Invalid command
E12 — Invalid output number
E13 — Invalid range
E22 — Busy
Timeout
Pauses of 10 seconds or longer between command ASCII characters result in a timeout.
The command operation is aborted with no other indication.
Using the Command and Response Table
The
Command and Response Table for SIS Commands
is on page 11. Commands in
the table are
NOT case sensitive. The ASCII to HEX conversion table, below, is for use with
the command and response table.
ASCII to Hex Conversion Table
•
Space
Symbol Definitions
Symbols (variables), defined below, are used in the command and response table. The
symbols represent variables in the command and response table fields.
]
= Carriage return/line feed
}
= Carriage return (no line feed)
E
=
•
= Space (hard) character
W
= Can be used interchangeably with the
E
character
|
= Can be used interchangeably with the
}
character
X!
= Input
00
through
08
(
00
= no input)
X@
= Mute/front panel lock status
0
= off (unmuted/unlocked)
1
= on (muted/locked)
X#
= Transceiver module status
0
= no module installed
1
= multimode
2
= singlemode
X$
= Firmware version
v.vv
X%
= Transceiver module status
0
= no light input
1
= light input
X^
= Temperature
nnn
F
= whole degree Fahrenheit
X&
= Input reclocker rate
00
= Bypass (no reclocking)
02
= 2.125 Gbps
01
= 1.25 Gbps
03
= 4.25 Gbps (
default)
X*
= Name
Up to 24 upper- and lower-case alphanumeric characters. Hyphen characters
are valid, blank and space characters are invalid. The first character must be a
letter. The last character may not be a hyphen.