FOX SW8 • Introduction

6

100-240V 0.3A

50/60 Hz

RS-232

Tx Rx

FOX SW8

OPTICAL INPUTS

LOOP IN

LOOP IN

LOOP IN

LOOP IN

LOOP IN

LOOP IN

LOOP IN

OUT IN

1

2

3

4

5

6

7

8

FOXBOX Tx HDMI #1

12V
1.0A MAX

POWER

FOXBOX Tx HDMI

AUDIO INPUT

RS-232

OVER FIBER ALARM

Tx Rx

1 2

HDMI INPUT

LINK

OPTICAL

Rx

Tx

LINK

FOXBOX Tx HDMI #7

FOXBOX Rx HDMI

12V
1.0A MAX

POWER

FOXBOX Tx HDMI

AUDIO INPUT

RS-232

OVER FIBER ALARM

Tx Rx

1 2

HDMI INPUT

LINK

OPTICAL

Rx

Tx

LINK

FOXBOX Tx HDMI #2

Transmitters 3 — 6

• • • • • • •

12V
1.0A MAX

POWER

FOXBOX Tx HDMI

AUDIO INPUT

RS-232

OVER FIBER ALARM

Tx Rx

1 2

HDMI INPUT

LINK

OPTICAL

Rx

Tx

LINK

12V
1.0A MAX

POWER

LINK

OPTICAL

Rx

Tx

LINK

HDMI AUDIO

HDMI

AUDIO

OUTPUTS

OFF

ON

REMOTE

RS-232

Tx Rx

RS-232

OVER FIBER ALARM

Tx Rx

1 2

L

R

FOXBOX Rx HDMI

Figure 4.

HDCP-Compliant Configuration

e

RS-232 port — For serial control of the switcher, connect a host device, such as a
computer, touch panel control, or RS-232 capable PDA, via this 3-pole captive screw
connector (see figure 5 to wire this connector).

Do not tin the wires!

Controlling

Device

Ground ( )
Receive (Rx)

Transmit (Tx)

Ground ( )
Receive (Rx)

Transmit (Tx)

Bidirectional

Tx Rx

NOTE: Cross the Tx and Rx lines once between the source and the target.

RS-232

Function

Pin

Tx

Rx

Gnd

Transmit data
Receive data
Signal ground

Figure 5.

RS-232 Connectors

NOTES:

The length of exposed wires is critical. The ideal length is 3/16 inches (5 mm).

If the stripped section of wire is longer than 3/16 inches, the exposed wires
may touch, causing a short circuit.

If the stripped section of wire is shorter than 3/16 inches, wires can be easily
pulled out even if tightly fastened by the captive screws.

This port is RS-232 only, with the following protocols:

9600 baud

no parity

8 data bits

1 stop bit

no flow control