beautypg.com

Power input – Extron Electronics DVI DL 201 Tx_Rx User Guide User Manual

Page 18

background image

Power Input

1.

Connect the captive screw connector from the supplied 12 VDC power supply into the
power receptacle.

CAUTION: Always use a power supply supplied by or specified by Extron. Use

of an unauthorized power supply voids all regulatory compliance
certification and may cause damage to the supply and the end
product.

Unless otherwise stated, the AC/DC adapters are not suitable for
use in air handling spaces or in wall cavities. The power supply is
to be located within the same vicinity as the Extron A/V processing
equipment in an ordinary location, Pollution Degree 2, secured to the
equipment rack within the dedicated closet, podium or desk.

The installation must always be in accordance with the applicable
provisions of National Electrical Code ANSI/NFPA 70, article 75 and the
Canadian Electrical Code part 1, section 16. The power supply shall
not be permanently fixed to building structure or similar structure.

Twisted pair cable 2, pin 5 carries a 12 VDC power signal. This remote powering
feature allows a single power supply, connected to the transmitter, to power both the
transmitter and receiver.

CAUTION: Power supply voltage polarity is critical. Incorrect voltage polarity

can damage the power supply, the transmitter, and/or the receiver.
Identify the ground ( ) lead by the ridges on the side of the cord (see
the figure below).

12V

0.4A MAX

POWER

Power Receptacle

DC Power Cord
Captive Screw Connector

AC Power Cord

Ground
+12 VDC

External

Power Supply

(12 VDC, 1 A )

Figure 6.

Connecting Power to DVI DL 201 Tx/Rx

NOTE: See the

second note

on page 10 for important information about wiring

captive screw connectors.

2.

Connect the AC power cord of the power supply unit to a 110 or 220 VAC electrical
source.

3.

When the transmitter or receiver is getting power, either directly from the power
supply or indirectly through the remote powering feature (receiver), the front panel
LED lights amber.

Power Supply

Output Cord

SECTION A–A

Ridges

Smooth

A

A

DVI DL 201 Tx/Rx • Panels and Cabling

12