Extron Electronics DVI DL 201 Tx_Rx User Guide User Manual

Page 14

background image

5.

Separate the individual wires, and arrange them so that all eight wires are side by side
in the same order as the T586A or T586B standard shown at the top of the next page.
Both ends of a cable must be wired to the same standard (T586A or T586B).

Pin # TIA/EIA

T 586 A

Wire color

TIA/EIA

T 586 B

Wire color

Cable 1 Cable 2

Cable 3

1

White-green

White-orange Data 0+

CEC

Data 3+

2

Green

Orange

Data 0+

HPD

Data 3+

3

White-orange

White-green

IDCK+

RS-232 Tx/IR+ N/C

4

Blue

Blue

Data 1+

DDC Clock

Data 4+

5

White-blue

White-blue

Data 1+

+12 V

Data 4+

6

Orange

Green

IDCK-

RS-232 Rx

N/C

7

White-brown

White-brown Data 2+

DDC Data

Data 5+

8

Brown

Brown

Data 2+

Ground

Data 5+

6.

Feed the wires into the RJ-45 connector.

12345678

Line up wires per chart,
then insert into RJ-45
connector.

7.

Crimp the cable in the normal manner (see the figure below), folding the tangs of the
connector over the shielded tape.

Crimped Connector

DVI DL 201 Tx/Rx • Panels and Cabling

8