5 electrical connections: general instructions, Electrical connections: general instructions -14 – YSI MIQ/Blue PS Set User Manual
Page 24
Installation
MIQ/Blue PS
3 - 14
ba76095e02
01/2013
3.5
Electrical connections: General instructions
Cable glands
All electric cables are fed into the enclosure of the MIQ/Blue PS from
below through prepared openings. Cable glands with different clamping
ranges are provided with the MIQ/Blue PS to provide sealing between
the cable and enclosure as well as for strain relief. Select the suitable
cable gland for the respective cable diameter:
Small, clamping range 4.5 to 10 mm. This cable gland is suitable for
all IQ S
ENSOR
N
ET
cables.
Large, clamping range 7 to 13 mm. This cable gland is required for
cable sheaths with an outer diameter of more than 10 mm and is
screwed into the enclosure via an extension piece.
Note
If necessary, you can order additional large cable glands as a set of 4
pieces (model EW/1, order number 480 051).
Sealing ring 20 x 15 x 1 mm
Cable gland M16
Blind plug
Sealing ring 20 x 15 x 1 mm
Extension piece M16/M20
Sealing ring 24 x 19 x 2 mm
Cable gland M20