Centripro, Residential water systems, Jet pump motor data and electrical components – Xylem BMAID R4 User Manual
Page 47
![background image](/manuals/310180/47/background.png)
PAGE 47
Residential Water Systems
CentriPro
a.o. SmIth motor Data
Gp
where used
a.o. Smith
hp
Volts phase
Service
max. load
watts
Circuit
Number
factor
amps
breaker
J04853
J05, HB705
C48J2DB11C3HF
½ 115/230
1
1.6
10.8/5.4
880
25/15
J05853
JL07N, HSJ07, XSH07, HB
C48K2DB11A4HH ¾ 115/230
1
1.5
14.8/7.4
1280
30/15
J06853
JL10N, HSJ10, SJ10, XSH10, HB
C48L2DB11A4HH
1
115/230
1
1.4
16.2/8.1
1440
30/20
J07858
HSJ15, SJ15, HB, XSH15
C48M2DB11A1HH 1½ 115/230
1
1.3
20.0/10.0
1866
40/20
J08854
HSJ20, HSC20, XSH20
K48N2DB11A2HH
2
115/230
1
1.2
22.6/11.3
2100
25/15
② J09853
XSH30, GT30
C56P2U11A3HH
3
230
1
1.15
17.2
3280
30
② J04853L J5(S), GB
C48A93A06
½ 115/230
1
1.6
10.8/5.4
968
25/15
② J05853L J7(S), GB, GT07, (H)SJ07, HSC07
C48A94A06
¾ 115/230
1
1.5
14.8/7.4
1336
30/15
② J06853L J10(S), GB, GT10, (H)SJ10, HSC10 C48A95A06
1
115/230
1
1.4
16.2/8.1
1592
30/20
② J07858L J15(S), GB, GT15, HSJ15, HSC15
C48M2DC11A1
1½ 115/230
1
1.3
21.4/10.7
1950
40/20
①② J08854L HSJ20, GB, GT20, HSC20
K48A34A06
2
230
1
1.2
12.9
2100
25
SFJ04853 JB05
S48A90A06
½ 115/230
1
1.6
9.4/4.7
900
20/10
SFJ05853 JB07
C48A77A06
¾ 115/230
1
1.5
13.6/6.8
1160
25/15
SFJ06853 JB10
C48A78A06
1 115/230
1
1.4
15.8/7.9
1400
30/20
② SFJ04860 JRS5, JRD5, JB05
C48C04A06
½
115/230
1
1.6
12.6/6.3
990
25/15
② SFJ05860 JRS7, JRD7, JB07
C48C05A06
¾
115/230
1
1.5
14.8/7.4
1200
30/15
② SFJ06860 JRS10, JRD10, JB10
C48C06A06
1
115/230
1
1.4
16.2/8.1
1400
30/20
①
Effective July, 1998, 230 V only. ② Current production motor
ElECtrICal CompoNENtS
Gp motor
a.o. Smith
motor overload with leads
run Capacitor
Start Capacitor
Switch⑤
model
motor model
④
old Number ③ New Number t.I. Number
and mfD
mfD rating
J04853
C48J2DB11C3HF
614246 71
MET38ABN
610807 1: 124/148
629002 2
J05853
C48K2DB11A4HH
614246 20
CET63ABN
610807 2: 161/192
629002 2
J06853
C48L2DB11A4HH
614246 9
CET52ABN
610807 2: 161/192
629002 2
J07858
C48M2DB11A1HH
614246 79
CET38ABM
610807 2: 161/192
629002 2
J08854
K48N2DB11A2HH
611307 29
BRT44ABM
614529 4: 25
610807 1: 124/148
629002 2
J09853
_ - 196427-20
611106 22
611106 36
BRB2938
628318 314: 55
610807 11; 36-43
629002 2
J04853L
C48A93A06
614246 98
627121 43
MET39ABN-CL
610807 1:124/148
629002 2
J05853L
C48A94A06
614246 20
627121 38
CET63ABN
610807 2:161/192
629002 2
J06853L
C48A95A06
614246 9
627121 7
CET52ABN
610807 2:161/192
629002 2
J07858L
C48C53A06
611123 21
BRT45ABM
610807 7:189/227
629002 2
J08854L
K48A34A06
616861 10
627119 10
CET31ABN
623450 8: 30
610807 33: 64-77
629002 2
SFJ04853 S48A90A06
621863 1
MEJ38ABN
N/A
3945C91A01
SFJ05853 C48A77A06
621863 4
CET55ABN
610807 2: 161/192
3945C91A01
SFJ06853 C48A78A06
621863 5
CET49ABN
610807 2: 161/192
3945C91A01
SFJ04860 C48C04A06
614246 67
627121 48
MET36ABN
610807 2: 161/192
629002 2
SFJ05860 C48C05A06
614246 20
627121 38
CET63ABN
610807 2: 161/192
629002 2
SFJ06860 C48C06A06
614246 9
627121 7
CET52ABN
610807 2: 161/192
629002 2
③
These new overload part numbers are for use with the new plastic terminal board with the quick change voltage plug.
Use this suffix if your motor has the old style brown terminal board without quick change voltage plug.
⑤
629002 2 replaces 614234 1, 2, and 6.
4
JEt pump motor Data aND ElECtrICal CompoNENtS