motor wINDING rESIStaNCE ChECkout

CablE ChECkout

Checking Cable and Splice
1. Submerge cable and splice in steel barrel of water

with both ends out of water.

2. Set ohmmeter selector on RX100K and adjust

needle to zero (0) by clipping ohmmeter leads
together.

3. After adjusting ohmmeter, clip one ohmmeter

lead to barrel and the other to each cable lead
individually, as shown.

4. If the needle deflects to zero (0) on any of the cable

leads, pull the splice up out of the water. If the
needle falls back to
(∞) (no reading) the

leak is in the splice.

5. If leak is not in the

splice, pull the cable
out of the water slowly
until needle falls back
to (∞) (no reading).

When the needle falls
back, the leak is at
that point.

6. If the cable or splice

is bad, it should be
repaired or replaced.

What It Means –

1. If all ohm values are

normal, the motor
windings are neither
shorted nor open, and the cable colors are
correct.

2. If any one ohm value is less than normal, the

motor is shorted.

3. If any one ohm value is greater than normal, the

winding or the cable is open or there is a poor
cable joint or connection.

4. If some ohm values are greater than normal and

some less, the leads are mixed.

measuring winding resistance

1. Set the scale lever to R x 1 for values under 10

ohms. For values over 10 ohms, set the scale
lever to R x 10. Zero balance the ohmmeter as
described earlier on page 11.

open master breaker and

disconnect all leads from

control box to pressure switch (q-D type

control, remove lid) to avoid damage to meter

or electric shock hazard.

2. Connect the ohmmeter leads as shown below.

tablE 2 – Cable resistance – Copper

Cable

DC resistance of Cable per 100 foot

Size

length ohms per pair of leads

14

.544

12

.338

10

.214

8

.135

6

.082

4

.052

2

.032

If aluminum cable is used the readings will be
higher. Divide the ohm readings on this chart

by 0.61 to
determine the
actual resistance
of aluminum
cable.

See motor data pages
for motor resistance
ratings.

RULE OF THUMB

Add resistance of drop cable when checking
pump in well. See Table 2 above.

CAUTION

Checking Cable and

Splice Test

Attach this lead

to Metal Tank

Ohmmeter

Set at R x 100K

OHMS

R x 1000

R x 10K

R x 100K

R x 100
R x 10
R x 1

ZERO

OHMS