Centripro, Residential water systems – Xylem BMAID R4 User Manual
Page 22
PAGE 22
Residential Water Systems
CentriPro
CSCr 1Ø CoNtrol boXES CapaCItor Start - CapaCItor ruN
for uSE wIth 3 wIrE, 1Ø, 4" CENtrIpro motorS aND 4" (6", 5 hp) fraNklIN ElECtrIC motorS
Control box
may
may replace
may replace
Standard
Standard
Dual Element Enclosure
Shipping
order
hp kw Volts replace
rJ #
fE #
Circuit
fuse
time Delay Dimensions
wt. (lbs)
Number
Gp #
breaker
fuse
w x D x h (in)
CB05412CR 0.5 .37 230
①
50F311CB
2824055015①
10
15
10
8.1 x 5.9 x 9.3
7
S50N1CB, A50N1CB
CB07412CR .75 .55 230
①
75F311CB
2824075015①
15
20
10
8.1 x 5.9 x 9.3
7
S75N1CB, A75N1CB
CB10412CR 1 .75 230
①
S100F311CB
2824085015①
15
20
10
8.1 x 5.9 x 9.3
7
S100N1CB, A100N1CB
CB15412CR 1.5 1.1 230 00074
150F311CB
282 3008 110
25
30
15
8.1 x 5.9 x 9.3
7
S150N1CB, A150N1CB
CB20412CR 2 1.5 230 00084
200F311CB
282 3018 110
25
30
20
8.1 x 5.9 x 9.3
7
S200N1CB, AS200T1CB
CB30412CR 3 2.2 230 00094
300F311CB
282 3028 110
40
45
25
8.1 x 5.9 x 9.3
7
S300N1CB
CB50412CR 5 3.7 230 00104
500F311CB
282 1138 110
60
80
45
8.1 x 5.9 x 9.3
8
S500N1CB
“k” rEpaIr partS
Control box
old Control
Capacitor
Capacitor Capacitor Capacitor Capacitor
overload
Start relay
order
hp Volts box order repair part
mfd.
type
Voltage ③ quantity order order
Number
Number
Number
Number
②
Number
CB05412CR .5 230
①
9K465 43-53 Start 250
1 NA 9K458
9K466
15
Run 370
CB07412CR .75 230
①
9K448 59-71 Start 250
1 N/A 9K458
9K467
23
Run 370
CB10412CR 1 230
①
9K449 86-103 Start 250
1 N/A 9K458
9K467
23
Run 370
CB15412CR 1.5 230
00074
9K447 105-126 Start 250
1 9K471 9K458
9K466
15
Run 370
CB20412CR 2 230 00084
9K447 105-126 Start 250
1 9K481 9K458
9K451
20
Run 370
CB30412CR 3 230 00094
9K453 208-250 Start 250
1 9K482
9K454
45
Run 370
9K459
CB50412CR 5 230 00104
9K455 270-324 Start 330
1
9K483
9K456
40
Run 370
2
①
New ½ – 1 HP CSCR control box is now in a larger enclosure, it is not in a quick disconnect style enclosure.
②
Overloads for 2, 3 and 5 HP CSCR boxes are sold prewired and soldered as an assembly. No field soldering or wiring required.
③
It is allowable to substitute capacitors with higher voltage ratings but never lower ratings. Mfd. ratings are mandatory.
Order Number 9K479 for 200/208 Volt Start Relay.