Centripro, Residential water systems, Hydropro and centripro tank selection – Xylem BMAID R4 User Manual
Page 46
![background image](/manuals/310180/46/background.png)
PAGE 46
Residential Water Systems
CentriPro
tablE 2 – prESSurE faCtorS
pump Cut-In pressure – pSIG
20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100
105 110
115
30 .22
35 .30 .20
40 .37 .27 .18
45 .42 .34 .25 .17
50 .46 .39 .31 .23 .15
55 .50 .43 .36 .29 .22 .14
60 .54 .47 .40 .33 .27 .20 .13
65 .50 .44 .38 .31 .25 .19 .13
70 .53 .47 .41 .35 .30 .24 .18 .12
75
.50 .45 .39 .33 .28 .22 .17 .11
80
.53 .48 .42 .37 .32 .26 .21 .16 .11
85
.50 .45 .40 .35 .30 .25 .20 .15 .10
90
.53 .48 .43 .38 .33 .29 .24 .19 .14 .10
95
.50 .46 .41 .36 .32 .27 .23 .18 .14 .09
100
.52 .48 .44 .39 .35 .31 .26 .22 .17 .13 .09
105
.50 .46 .42 .38 .33 .29 .25 .21 .17 .13 .08
110
.52 .46 .44 .40 .36 .32 .28 .24 .20 .16 .12
115
.50 .46 .42 .39 .35 .31 .27 .23 .19 .15 .12 .06
120
.52 .48 .45 .41 .37 .33 .30 .26 .22 .19 .15 .11
125
.50 .47 .43 .39 .36 .32 .29 .25 .21 .16 .14 .11 .07
To determine tank drawdown of operating pressure ranges other than those listed in table, use following procedure:
Multiply total tank volume (table 1) by pressure factor (table 4).
Example: Operating range: 35/55
Tank being used: V-200
65.1 = Total volume of tank (table 1)
x .29
Pressure factor (table 4)
18.9 = Drawdown in gallons at 35/55 PSI operating range.
pump Cut-
o
ut
pr
essur
e –
p
SIG
tablE 1 – taNk moDElS – See your Full Line Catalog Tank Bulletins for a listing of all available models.
①
Drawdown based on a 22 psi differential and Boyle’s Law. Tem-
perature, elevation and pressure can all affect drawdown volume.
hyDropro aND CENtrIpro taNk SElECtIoN
tank Drawdown pressure factors using an “Extra”
2 pSI of Drawdown
pressure Differential
factor with extra 2 psi*
18 – 40
.402
28 – 50
.340
38 – 60
.295
48 – 70
.260
To Calculate drawdown capacity multiply: Factor x Tank Volume.
model
No.
total
Volume
(Gals.)
①
Drawdown in Gals. at System
operating pressure range of
maximum
Drawdown
Volume
(Gallons)
18/40
pSIG
28/50
pSIG
38/60
pSIG
V6P
1.9
0.7
0.6
0.5
1.3
V15P
4.9
1.8
1.5
1.4
3.1
V25P
7.3
2.7
2.3
2.1
3.1
V45P
13.9
5.6
4.7
4.1
8.4
V45
13.9
5.6
4.7
4.1
8.4
V60B
19.9
8.0
6.8
5.8
12.1
V60
19.9
8.0
6.8
5.8
12.1
V80
25.9
10.4
8.8
7.6
13.9
V80EX
25.9
10.4
8.8
7.6
13.9
V100
31.8
12.8
10.8
9.4
13.8
V100S
31.8
12.8
10.8
9.4
13.8
V140B
45.2
18.2
15.4
13.3
27.3
V140
45.2
18.2
15.4
13.3
27.3
V200
65.1
26.2
22.1
19.2
39.3
V250
83.5
33.6
28.4
25.6
50.8
V260
84.9
34.1
28.9
25.0
44.7
V350
115.9
46.6
39.4
34.1
70.5