Residential Water Systems

CentriPro

1Ø thrEE-wIrE CoNtrol boX wIrING ChartS
quick Disconnect ½ – 1 hp

wIrING DIaGram

“k” rEpaIr partS for quICk DISCoNNECt StylE CoNtrol boXES

order

Capacitor

Start Capacitor

Start relay

Standard

relay (ohms)

Number

hp

Volts

order

Capacitor

Voltage /

order No.

Circuit breaker

#2-#5

Number

mfd

quantity

CB05411

.5

115

9K450

250 - 300

125 / 1

9K457

30

700 – 1800

9K566

CB05412

.5

230

9K448

59 - 71

250 / 1

9K462

15

CB07412

.75

230

9K449

86 - 103

250 / 1

9K567

20

4500 – 7000

CB10412

1

230

9K447

105 - 126

250 / 1

25

First Design - Up to June 2009 - Relay tab on bottom, capacitor held by bracket and screw. See pictures below. 208 V use 9K461 relay.

Current Design - Starting June 2009 - Relay tab on top and capacitors, all held by one screw. See pictures below. The relays are designed

for operation in a specific orientation, therefore there are two different numbers now. 208 V use 9K568 relay.

First Design

Tab Down ➀

Current Design

Tab Up ➁