Armasight IAIR002LP000001 DRAKOS 2 Multi-Spectral Laser Aiming/ Illumination Devices User Manual
Page 29

29
SEQ
NO.
LOCATION/
ITEM TO
INSPECT/ CHECK/
SERVICE
PROCEDURE
NOT FULLY MISSION
CAPABLE IF...
OPERATIONAL CHECKS
WARNINGS:
NEVER LOOK INTO THE LASER BEAM.
When performing operational checks, beware of reflections from optical
surfaces.
NOTE:
You must wear NVG when checking IR channel(s).
10 Aiming Laser(s)
Install the battery. Turn the switch
to the position corresponding
to the minimum laser output of
the aiming channel. Push the ON
button down to activate the laser.
Direct the radiated beam at a wall
from a distance of about 5m. A red
(infrared) dot should appear on the
wall. To see an infrared dot, look
through the NVG.
No aiming dot.
11 Remote
Control Unit
Push the ON button down again to
actuate standby mode. Push the
remote control button down to acti-
vate the laser. A red (infrared) dot
should appear on the wall.
No aiming dot.
12 IR Illuminator
Turn the switch to the position
corresponding to the minimum
laser output of the IR illuminator.
Activate the laser. Direct the radi-
ated beam at a wall from a distance
of about 5m. Look through the NVG.
A spot of light should appear on
the wall.
No light appears
on the wall.
13 Boresight
Perform boresight testing as per
Part 4.3.3.
Adjustment
mechanisms are
inoperative.
TABLE 4-1. CONTINUED