GE Industrial Solutions AF-650 GP Encoder Module User Manual
Af-650 gp

1
AF-650 GP
TM
General Purpose Drive
Encoder Option Module (OPCENC)
The encoder module can be used as feedback source for closed loop Flux control (par. H-42) as well
as closed loop speed control (par. PI-00). Conf igure encoder option in parameter group EC-##.
Used for:
• Advanced Vector Control closed loop
• Flux Vector Speed control
• Flux Vector Torque control
• Permanent magnet motor
Supported encoder types:
Incremental Encoder: 5 V TTL type, RS422, max. frequency: 410 kHz
Incremental Enocer: 1Vpp, Sine-Cosine
Hiperface® Encoder: Absolute and Sine-Cosine (Stegmann/SICK)
EnDat Encoder: Absolute and Sine-Cosine (Heidenhain) Supports version 2.1
SSI Encoder: Absolute
Encoder monitor:
The 4 encoder channels (S, B, Z and D) are monitored, open and short circuit can be detected.
There is a green LED for each channel which lights up when the channel is OK.
NOTE!
The LEDs are only visible when removing the keypad. In case of
an encoder error please see par. EC-61: None, Warning or Trip.
When the encoder option kit is ordered separately the kit includes:
•
Encoder Option Module (OPCENC)
•
Larger keypad cradle and terminal cover for Unit Size 12, 13 and 23 drives (230V to 10
HP & 460/575V to 20 HP)
Terminal Designation
X31/ #(#)
Incremental Encoder
(please refer to
Graphic A)
SinCos Encoder Hiperface®
(please refer to Graphic B)
EnDat Encoder
SSI Encoder
Description
1
NC
NC
NC
24 V
24 V Output (21-25 V), Imax: 125 mA)
2
NC
8 VCC
NC
NC
8 V Output (7-12 V, Imax: 200 mA)
3
5 VCC
NC
5 VCC
5 V
5 V Output (5 V ± 5%, Imax: 200 mA)
4
GND
+COS
GND
GND
GND
5
A input
REFCOS
+COS
A input
A input
6
A inv input
NC
REFCOS
A input inv.
A inv input
7
B input
+SIN
+SIN
B input
B input
8
B inv input
REFSIN
REFSIN
B input inv.
B inv input
9
Z input
+Data RS485
Clock out
Clock out
Z input OR +Data RS485
10
Z inv input
-Data RS485
Clock out inv.
Clock out inv. Z input OR -Data RS485
11
NC
NC
Data in
Data in
Future use
12
NC
NC
Data in inv.
Data in inv.
Future use
Max. 5V on terminal 12.