Feature specifications – GE Industrial Solutions EHW007A0B Series (Eighth-Brick) User Manual
Page 4

Data Sheet
October 2, 2009
EHW007A0B Series Eighth-Brick Power Modules
36–75Vdc Input; 12.0Vdc Output; 7A Output Current
LINEAGE
POWER
4
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions. See Feature Descriptions for additional information.
Parameter
Device
Symbol
Min
Typ
Max
Unit
Remote On/Off Signal Interface
(V
IN
=V
IN, min
to V
IN, max
; open collector or equivalent,
Signal referenced to V
IN-
terminal)
Negative Logic: device code suffix “1”
Logic Low = module On, Logic High = module Off
Positive Logic: No device code suffix required
Logic Low = module Off, Logic High = module On
Logic Low - Remote On/Off Current
All
I
on/off
⎯
0.3 1.0 mA
Logic Low - On/Off Voltage
All
V
on/off
-0.7
⎯
1.2 V
dc
Logic High Voltage – (Typ = Open Collector)
All
V
on/off
⎯
5 V
dc
Logic High maximum allowable leakage current
All
I
on/off
⎯
⎯
10
μA
Turn-On Delay and Rise Times
(I
O
=I
O, max ,
V
IN
=V
IN, nom,
T
A
= 25
o
C)
Case 1: Input power is applied for at least 1 second
and then the On/Off input is set from OFF to ON (T
delay
= from instant at which V
IN
=V
IN, min
until V
O
= 10% of V
O,
)
All T
delay
― 20 ― msec
Case 2: On/Off input is set to Logic Low (Module
ON) and then input power is applied (T
delay
from
instant at which V
IN
= V
IN, min
until V
o
=10% of V
O,set
)
All T
delay
―
― 150 msec
Output voltage Rise time (time for V
o
to rise from 10%
of V
o,set
to 90% of V
o, set
)
All T
rise
― 5 12 msec
Output voltage overshoot – Startup
I
O
= I
O, max
; V
IN
=V
IN, min
to V
IN, max
, T
A
= 25
o
C
All
― 3
%
V
O, set
Remote Sense Range
All
V
SENSE
10 %
V
O, set
Output Voltage Adjustment Range
All
90
110
% V
O, set
Output Overvoltage Protection
All V
O, limit
13.8
⎯
16.5 V
dc
Overtemperature Protection – Hiccup Auto Restart
All
T
ref
⎯
135
⎯
O
C
Input Undervoltage Lockout
All
V
UVLO
Turn-on Threshold
⎯
34 36 V
dc
Turn-off Threshold
30 32
⎯
V
dc
Hysterisis
1
2
3
V
dc
Input Overvoltage Lockout
All
V
OVLO
Turn-on Threshold
76
79
⎯
Vdc
Turn-off Threshold
⎯
81 83 Vdc
Hysterisis
1
2
⎯
Vdc