Page 80
Economical long-life light sources with plug-in bases
Compact Fluorescent Lamps OSRAM DULUX
®
Technical Guide
78
Lamp
P [W]
Q [J]
Rsub [
Ω]
min
max
min
max
min
max
OSRAM DULUX
®
S/E 7 W
0.5
1.0
1.0
2.0
30
40
OSRAM DULUX
®
S/E 9 W
0.5
1.0
1.0
2.0
30
40
OSRAM DULUX
®
S/E 11 W
0.5
1.0
1.0
2.0
30
40
OSRAM DULUX
®
D/E 10 W
0.6
1.2
1.0
2.0
30
40
OSRAM DULUX
®
D/E 13 W
0.7
1.4
1.0
2.0
30
40
OSRAM DULUX
®
D/E 18 W
3)
0.7
1.4
0.9
1.8
18
24
OSRAM DULUX
®
D/E 26 W
3)
0.8
1.6
1.0
2.0
9
12
OSRAM DULUX
®
T/E 13 W
0.7
1.4
1.0
2.0
30
40
OSRAM DULUX
®
T/E 18 W
0.7
1.4
0.9
1.8
18
24
OSRAM DULUX
®
T/E 26 W
1)
0.8
1.6
1.0
2.0
9
12
OSRAM DULUX
®
T/E 32 W
1) 3)
0.8
1.6
1.0
2.0
9
12
OSRAM DULUX
®
T/E 42 W
1)
3)
0.8
1.6
1.0
2.0
9
12
OSRAM DULUX
®
T/E 11W HE
0.7
1.4
1.0
2.0
30
40
OSRAM DULUX
®
T/E 14W HE
0.7
1.4
1.0
2.0
30
40
OSRAM DULUX
®
T/E 17W HE
0.7
1.4
1.0
2.0
30
40
OSRAM DULUX
®
L 18 W
3)
0.9
1.8
1.5
3.0
8
11
OSRAM DULUX
®
L 24 W
3)
0.9
1.8
1.5
3.0
8
11
OSRAM DULUX
®
L 36 W
3)
1.0
2.0
1.6
3.2
7
9
OSRAM DULUX
®
L 40 W
1)
0.9
1.8
1.5
3.0
8
11
OSRAM DULUX
®
L 55 W
1)
3)
1.1
2.2
2.4
4.8
5
6.5
OSRAM DULUX
®
L 80 W
1)
1.5
3.0
2.4
4.8
5
6.5
OSRAM DULUX
®
L 16 W HE
0.75
1.5
0.9
1.8
30
45
OSRAM DULUX
®
L 22 W HE
0.75
1.5
0.9
1.8
30
45
OSRAM DULUX
®
L 26 W HE
0.75
1.5
0.9
1.8
30
45
OSRAM DULUX
®
L 28 W HE
0.75
1.5
0.9
1.8
30
45
OSRAM DULUX
®
F 18 W
0.9
1.8
1.5
3.0
8
11
OSRAM DULUX
®
F 24 W
0.9
1.8
1.5
3.0
8
11
OSRAM DULUX
®
F 36 W
1.0
2.0
1.6
3.2
7
9
CFL SQUARE
®
16W
2)
0.6
1.2
0.9
1.8
40
50
CFL SQUARE
®
28W
2)
0.9
1.8
1.1
2.2
12
16
CFL SQUARE
®
38W
2)
1.0
2.0
2.0
4.0
5.6
8.2
1) Also for DULUX
®
CONSTANT
2) CFL SQUARE
®®
four-pin base
3) also for XT versions
5.1.2 Starting (ECG operation)
The lamp should not ignite during the preheating time; the open-circuit voltage of the ECG must
therefore not exceed a lamp-specific maximum value. After the preheating phase the lamp should
ignite reliably; the open-circuit voltage of the ECG must therefore not fall below a lamp-specific
minimum value. The following table contains the permissible or necessary limit values for the open-
circuit voltage of the ECG. Because of the temperature response of the ignition voltage of
fluorescent lamps and compact fluorescent lamps, these values are given for two ambient
temperature ranges.