Economical long-life light sources with plug-in bases

Compact Fluorescent Lamps OSRAM DULUX

®

Technical Guide

33

2.2.3 Inductive operation Series circuit

Series circuits (tandem circuits) are possible only for certain types of lamps in which the arc voltage
does not exceed certain values (see 3.2.1 Permissible lamp/CCG combinations and system data,
p. 47).

Measurement conditions according to IEC 60901:

220 V / 50 Hz supply voltage1)

Operation on reference gear

Ambient temperature 25°C

Lamps aged 100 hours

Base-up position for OSRAM DULUX

®

S

Horizontal position for OSRAM DULUX

®

L, F

Lamp
reference

Luminous

flux

lm

Lamp

Wattage

W

Luminous

efficacy

lm/W

Arc

Voltage

V

Lamp

current

mA

Calibra-

tion

current

mA

Impe-

dance

Power

factor

2x DULUX

®

S 5W

515

11

-

35

180

170

1070

0.12

2x DULUX

®

S 7W

820

13.7

-

47

160

170

1070

0.12

2x DULUX

®

S 9W

950

14.4

-

60

130

170

1070

0.12

2x DULUX

®

L 18W (XT)

2500

38

-

58

425

370

390

0.12

2x DULUX

®

F 18W

2300

38

-

56

425

370

390

0.12

1)

In accordance with IEC 60901, measurements are taken at 220 V/50 Hz on the reference control gear. However, there is no change in the
electrical lamp data for 230 V and 240 V supplies, provided suitable control gear is used.

2.2.4 Inductive operation Lead-lag circuit

With certain lamps in two-lamp inductive arrangements, a lead-lag circuit can be set up in which
one of the two CCGs is combined with a series capacitor. For the capacitor data see 3.2.2
Compensation.