Economical long-life light sources with plug-in bases

Compact Fluorescent Lamps OSRAM DULUX

®

Technical Guide

13

OSRAM DULUX® L HE

Ambient temperature

25°C

35°C

16 W

1500 lm

1600 lm

22 W

2055 lm

2200 lm

26 W

2470 lm

2600 lm

28 W

2700 lm

2800 lm


Light colours 830, 840

2GX11, 4 pin base

Average life time: 20,000 h for ECG operation

Is a high efficiency compact fluorescent lamp with a very high energy efficiency of 100lm/W. The
lamp offers new possibilities by designing new energy and cost efficient lighting solutions.

The DULUX

®

L HE lamp uses a new lamp base/holder system. So it is not suitable for 1:1 retrofits.

DULUX

®

L HE can only be operated in combination with electronic control gear.

A suitable control gear range is available, and can be supplied together with the lamps.

1.2.4 Lamps with four-pin bases for conventional or ECG operation

OSRAM DULUX® L

18 W

1200 lm

24 W

1800 lm

36 W

2900 lm

40 W *

3500 lm

55 W *

4800 lm

80 W *

6000 lm

* Only for ECG operation


Light colours
LUMILUX

®

827, 830, 840, 860**, 880**

** reduced luminous flux. Consult

www.osram.com


2G11, 4 pin base

Average life time:
10,000 h for CCG operation
20,000 h for ECG operation

OSRAM DULUX

®

L lamps are compact fluorescent lamps with a high luminous flux. They have al-

most the same luminous flux and power consumption as tubular fluorescent lamps but are less than
half as long and are more compact than U-shaped and ring-shaped lamps. OSRAM DULUX

®

L are

the ideal light source for modern space-saving wall and ceiling lighting in offices, shops, exhibition
rooms, foyers and canteens. They are also used for display and outdoor lighting.

OSRAM DULUX

®

L 18, 24 and 36 W lamps can be used with conventional control gear or appropri-

ate electronic control gear, such as QUICKTRONIC

®

. These lamps can also be dimmed in conjunc-

tion with suitable electronic control gear.

If used with conventional control gear and external starter, a power factor correction capacitor is
needed to improve voltage current phase shift.