beautypg.com

Teccor, Brand thyristors, Ev series 1.5 amp sensitive scrs – Littelfuse Sx02xS Series User Manual

Page 3

background image

229

Revised: 09/23/13

©2013 Littelfuse, Inc

Specifications are subject to change without notice.

Teccor

®

brand Thyristors

EV Series 1.5 Amp Sensitive SCRs

Sx02xS Series

Figure 2: Normalized DC Holding Current

vs. Junction Temperature

(I

H

@ T

J

/ I

H

@2

5

∞C)

Nor

maliz

ed Holding Cur

rent

-40

-25

-10

+5

+20

+35

+50

+65

+80

0.0

0.5

1.0

1.5

2.0

+95

+125

+110

Junction Temperature (T

J

) °C

Figure 5: Maximum Allowable Case Temperature

vs. On-State Current

0.0

0.5

1.0

50

RMS On-state Current [I

T (RMS)

] (Amps)

Max Allo

w

able

Case

Temper

at

ur

e,

T

C

(Celsius)

1.5

60

70

80

90

100

110

120

130

SOT-223

TO-92

CURRENT WAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 180

o

CASE TEMPERATURE: Measured as
shown on dimensional drawings

Figure 3: Normalized DC Gate Trigger Voltage

vs. Junction Temperature

(V

GT

@

T

j

/

V

GT

@

2

5

ºC)

-40

-25

-10

+5

+20

+35

+50

+65

+80

+95

+110

+125

0.5

1.0

1.5

Nor

maliz

ed Gat

e:

T

rigg

er

V

oltag

e

Junction Temperature (T

J

) °C

Figure 1: Normalized DC Gate Trigger Current

vs. Junction Temperature

-40

-10

+20

+50

+80

0.0

0.5

1.0

1.5

2.0

Junction Temperature (T

J

) °C

+95

Nor

maliz

ed Gat

e:

T

rigg

er Cur

rent

I

GT

@

T

j

/ I

GT

@ 2

5

ºC

+65

+35

+5

-25

+125

+110

2.5

0.0

0.5

1.0

0.0

A

v

er

ag

e P

o

w

er Dissipation,

P

D

(W

at

ts)

1.5

0.5

1.0

1.5

RMS On-state Current [I

T(RMS)

] (Amps)

CURRENT WAVEFORM: Sinusoidal
LOAD: Resistive or Inductive
CONDUCTION ANGLE: 180

o

Figure 4: Power Dissipation (Typical)

vs. RMS On-State Current