beautypg.com

Littelfuse MG12300D-BN2MM Series User Manual

Power module, 1200v igbt family

background image

Power Module

©2013 Littelfuse, Inc

Specifications are subject to change without notice.

Revised:08/06/13

1

MG12300D-BN2MM

1200V IGBT Family

MG12300D-BN2MM Series 300A Dual IGBT

Features

Applications

• High short circuit

capability,self limiting
short circuit current

• IGBT

3

CHIP(Trench+Field

Stop technology)

• V

CE(sat)

with positive

temperature coefficient

• Fast switching and short

tail current

• Free wheeling diodes

with fast and soft reverse
recovery

• Low switching losses

Absolute Maximum Ratings

(T

C

= 25°C, unless otherwise specified)

Symbol

Parameters

Test Conditions

Values

Unit

IGBT
V

CES

Collector - Emitter Voltage

T

Vj

=25°C

1200

V

V

GES

Gate - Emitter Voltage

±20

V

I

C

DC Collector Current

T

C

=25°C

480

A

T

C

=80°C

300

A

I

CM

Repetitive Peak Collector Current

t

p

=1ms

600

A

P

tot

Power Dissipation Per IGBT

1450

W

Diode
V

RRM

Repetitive Reverse Voltage

T

Vj

=25°C

1200

V

I

F(AV)

Average Forward Current

T

C

=25°C

480

A

T

C

=80°C

300

A

I

FRM

Repetitive Peak Forward Current

t

p

=1ms

600

A

I

2

t

T

Vj

=125°C, t=10ms, V

R

=0V

18000

A

2

s

Module Characteristics

(T

C

= 25°C, unless otherwise specified)

Symbol

Parameters

Test Conditions

Min

Typ

Max

Unit

T

Vj max)

Max. Junction Temperature

150

°C

T

Vj op

Operating Temperature

-40

125

°C

T

stg

Storage Temperature

-40

125

°C

V

isol

Insulation Test Voltage

AC, t=1min

3000

V

CTI

Comparative Tracking Index

Module case exposed to 0.1% ammonium

chloride solution per UL and IEC standards

350

V

Torque

Module-to-Sink

Recommended (M6)

3

5

N·m

Torque

Module Electrodes

Recommended (M6)

2.5

5

N·m

Weight

320

g

• Motor drives
• Inverter
• Converter

• SMPS and UPS
• Welder
• Induction Heating

Life Support Note:
Not Intended for Use in Life Support or Life Saving Applications
The products shown herein are not designed for use in life sustaining or life saving
applications unless otherwise expressly indicated.

RoHS

AGENCY

AGENCY FILE NUMBER

E71639

Agency Approvals