Permanent dryer controller programming example – Dexter Laundry T-80 Reversing (On-Premise) User Manual
Page 22

22
Go to the next step.
9) Press and release the SELECT/ENTER key. Once this key is pressed and released, the
temperature L.E.D. will switch off, the dry cycle L.E.D. and programming L.E.D. will remain
on, and the cool down L.E.D. will illuminate. The cool down time will also be shown on the
4-digit numeric display.
10) Press and release the UP or DOWN arrow keys to change the cool down time. Once either of
the arrow keys is pressed, the cool down L.E.D. and the cool down time on the 4-digit
numeric display will flash. If you press and hold either arrow key down, you will increment
(UP arrow) or decrement (DOWN arrow) through the cool down times available (2 through
60 minutes if the controller has a red dot sticker or 2 through 15 minutes if the controller has
no red dot sticker). To not change the cool down time, do not press the arrow keys. Go to
the next step.
11) Press and release the SELECT/ENTER key. Once this key is pressed and released, the cool
down L.E.D. will switch off, the dry cycle L.E.D. and programming L.E.D. will remain on,
and the reversing L.E.D. will illuminate. Either “rEv” (reversing mode) or “nrEv” (non-
reversing mode) will also be shown on the 4-digit numeric display.
12) Press and release the UP or DOWN arrow keys to switch between reversing and non-
reversing operation. Once either of the arrow keys is pressed, the reversing L.E.D. and the
“rEv” (reversing mode) or the “nrEv” (non-reversing mode) shown on the 4-digit numeric
display will flash. To not change the reversing or non-reversing mode of operation, do not
press the arrow keys. Go to the next step.
13) Press and release the SELECT/ENTER key. Once this key is pressed and released, the
reversing L.E.D. will switch off, the dry cycle L.E.D. and programming L.E.D. will remain
on. The 4-digit numeric display will change to “Prog”.
14) Press and release the STOP key to save the cycle program and escape the programming
mode. If you want to change the same dry cycle program again, press the SELECT/ENTER
key and continue at step 6 of this procedure. If you want to modify another dry cycle
program, go to step 4 of this procedure and continue.
15) If you pressed the STOP key to escape the programming mode, you may now start the dry
cycle by pressing the START key.
PERMANENT DRYER CONTROLLER PROGRAMMING
EXAMPLE
REQUIREMENTS: Dry a load, in reverse mode, with 50 minutes of actual heat at 195
o
F and
three minutes of cool down.
The following procedure will show you how to permanently modify the existing dry cycle 5
program for one cycle of drying. It is based on the assumption that the factory defaults have not