beautypg.com

Dexter Laundry T-80 Reversing (On-Premise) User Manual

Page 14

background image


14

4-DIGIT NUMERICAL DISPLAY MESSAGES - continued

Message

Description


Prog

This message is displayed when entering the permanent

programming

mode.


.15

This message appears while the dryer is in the heating time
of a dry cycle. The decimal point will blink if the output
for the gas valve is on, or remain on constantly if the output
for the gas valve is not on. The number represents the total
time left in the dry cycle (includes cool down time).


C02

This message appears when the cool down time of the dry
cycle is reached. The letter “C” represents the cool down
(non-heating) part of the dry cycle. The number(s) after the
letter “C” represent(s) the total time remaining in the dry
cycle.


F5

This message appears if there is a dryer fault. The letter
“F” indicates a fault and the number after the “F”
represents the specific fault that has occurred. There are
five different faults that can appear (F1 through F5).


rEv

This message is displayed, while in the programming mode,
to indicate the reversing function during the dry cycle.


nrEv

This message is displayed, while in the programming mode,
to indicate the non-reversing function during the dry cycle.