REVERSING DRYER CONTROLLER FACTORY DEFAULT PROGRAM
SETTINGS
DRY
CYCLE
DRYER
DIRECTION
COOL
DOWN
TIME
(MINUTES)
TOTAL
CYCLE
TIME
(MINUTES)
DRYING
TEMPERATURE
(
0
F) (
0
C)
DRYER LOAD
1 REV.
5
35 180
82
Towels, pads,
heavy cotton
2 REV.
2
20 170
77
Sheets, blended
materials
3 REV.
5
25 180
82
Cotton
4 NON-REV.
2
20
130 54
Synthetic
materials
5 NON-REV.
2
25
175 79
Blended materials
REVERSING DRYER FAULT CODES
FAULT#
FAULT
DESCRIPTION
ACTION
F1
Shorted thermostat
sensor.
Dryer stops and “F1” flashes on the 4-digit display. When
short circuit on sensor input is removed, “LOAd” appears
on the 4-digit display and the remaining dry time is reset.
F2
Open thermostat
sensor.
Dryer stops and “F2” flashes on the 4-digit display. When
a good sensor is connected to sensor input, “LOAd”
appears on the 4-digit display and the remaining dry time
is reset.
F3 EEPROM
corrupted.
Dryer will not start and “F3” appears on the 4-digit
display. The power to the dryer must be cycled to reset
the controller. Fault should only occur when starting a dry
cycle.
F4
Gas valve on fault.
The drying temperature did not increase 1
O
F. in 5 minutes.
“F4” will flash on the display and the dry cycle will finish
without calling for heat (energizing gas valve). Opening
the door or pressing the STOP key will reset the fault and
clear the remaining time in the dry cycle.
F5 Temperature
fault.
The drying temperature is at least 25
O
F. above the
temperature setting. “F5” will flash on the 4-digit display
and the dry cycle will finish without calling for heat
(energizing the gas valve). The power to the dryer must
be cycled to reset the controller.